1 / 7

Linac4 collimation

Linac4 collimation. Juan Luis Fernandez-Hernando, ASTeC/Cockcroft Institute 3 rd SPL workshop, 11-13 th November 2009. Linac4 Collimation. Used halo distribution at 23m downstream of the last PIMS module of Linac4. This distribution represents 3% of the total beam particles.

brie
Download Presentation

Linac4 collimation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Linac4 collimation Juan Luis Fernandez-Hernando, ASTeC/Cockcroft Institute 3rd SPL workshop, 11-13th November 2009

  2. Linac4 Collimation • Used halo distribution at 23m downstream of the last PIMS module of Linac4. • This distribution represents 3% of the total beam particles. • Beam power of 7.7kW, 2Hz of operation. • Estimated • required gaps for adjustable rectangular collimators (in each transverse plane and separated by ~5 cm) located at ~23m from the PIMS. • Dose rates in surrounding areas • If required, local shielding of collimators can be designed once the acceptable cooling time is decided Luis Fernandez-Hernando, 3rd SPL workshop

  3. Halo distribution at 23m downstream of the last PIMS module of Linac4. Collimator jaws made of graphite (low Z material to avoid excessive neutron generation). Length of each jaw set to 20cm. Y(cm) Half gaps for each jaw absorbing same power: 10W: x-hgap=1.28cm, y-hgap=2.25cm25W: x-hgap=1.15cm, y-hgap=1.80cm50W: x-hgap=1.08cm, y-hgap=1.46cm X(cm) Equal half gaps: 10W: x-hgap=1.89cm, y-hgap=1.89cm All 10W absorbed by the vertical jaws 25W: x-hgap=1.48cm, y-hgap=1.48cm 96% of the 25W absorbed by the vertical jaws50W: x-hgap=1.24cm, y-hgap=1.24cm 86% of the 50W absorbed by the vertical jaws Luis Fernandez-Hernando, 3rd SPL workshop

  4. Equivalent radiation dose rate after 1 month of operation at 2Hz for 50W power absorption. Dose rate values are similar at 25W and 10W power absorption. Max equivalent radiation dose rate: 540 µSv/h Max equiv. rad. dose rate 1 m away radially: 4 µSv/h Right after 1 month of constant operation Luis Fernandez-Hernando, 3rd SPL workshop

  5. Equivalent radiation dose rate after 1 month of operation at 2Hz for 50W power absorption. Dose rate values are similar at 25W and 10W power absorption. Max equivalent radiation dose rate: 35 µSv/h Max equiv. rad. dose rate 1 m away radially: 2 µSv/h After 1 hour cooling time Luis Fernandez-Hernando, 3rd SPL workshop

  6. Equivalent radiation dose rate after 1 month of operation at 2Hz for 50W power absorption. Dose rate values are similar at 25W and 10W power absorption. Max equivalent radiation dose rate: 15 µSv/h Max equiv. rad. dose rate 1 m away radially: 2 µSv/h After 1 day cooling time Luis Fernandez-Hernando, 3rd SPL workshop

  7. Summary and outlook: Once a location has been set a more detailed simulation will define the residual dose rates, absorbed dose for neighbouring components and activation of collimator jaws. In case we want to avoid some components to absorb more dose than it should, local shielding options would be studied. Another collimator at a different phase will be needed in order to properly collimate the beam. Luis Fernandez-Hernando, 3rd SPL workshop

More Related