TS-1000 ELECTRONIC TORQUE METER. State-of-the-art torque meter for: Service and Repair Production and Assembly Torque Wrench Calibration. Click here to run demo. Click here for safety warnings. HOW IT WORKS.

Download Presentation

TS-1000 ELECTRONIC TORQUE METER

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Ts 1000 electronic torque meter

TS-1000ELECTRONIC TORQUE METER

  • State-of-the-art torque meter for:

    • Service and Repair

      • Production and Assembly

        • Torque Wrench Calibration

Click here to run demo

Click here for safety warnings


How it works

HOW IT WORKS

The electronic torque meter connects to different types of torque transducers and displays the torque in real time torque units on a large digital LCD.

You can read the actual applied torque with great accuracy.

You can quickly set a target torque so the meter will prompt you if thetorque is within the desired limits.


Two types of transducers are available

TWO TYPES OF TRANSDUCERS ARE AVAILABLE

  • 1% In-line extension style

  • 0.5% Bench top style.


In line transducers

IN-LINE TRANSDUCERS

One type of transducer, the in-line torque transducer, attaches between a wrench and the socket just like a conventional extension.It can be installed on a torque wrench to verify the output or record the torque

or it can be installed on a conventional ratchet and used as an accurate digital torque wrench.


In line extension transducers

IN-LINE EXTENSIONTRANSDUCERS

  • 1% or better accuracy

  • Converts system into an accurate digital torque wrench.

  • Install between ratchet and socket

Use straight female-male adapters if needed with no change in accuracy


Bench top transducers

BENCH TOP TRANSDUCERS

  • For torque tester/cal lab applications.

  • Calibrate/test all type torque wrenches

  • .5% or better accuracy

  • Converts meter into an ANSI type I, II or III tester

  • NIST traceable Cert. supplied

Perfect for Calibration Labs.


Mix and match transducer types with one meter

Purchase one meter and use it with any type or range transducer.

All transducers are “plug-and-play”

Auto range detect

Auto calibration set-up

Auto Units set-up

MIX AND MATCH TRANSDUCERTYPES WITH ONE METER

You can expand the system as your needs change


Available torque ranges

AVAILABLE TORQUE RANGES:

  • Torque transducer ranges are available from 20 in.lb. to 500 ft.lb.

  • Other ranges, as low as 2 in.oz. and up to 9000 ft.lb. are available for special order.


Benefits

BENEFITS

  • Sends torque data to a printer or computer for documentation.

  • Has settable target torque with lights and buzzer that tell you when to stop pulling on the wrench. Or if a tested wrench is in calibration.

  • ISO 9000 may require documentation of torque accuracy.

  • 4 times more accurate than a torque wrench.

  • Documents the actual torque reading (has memory).

  • Allows you to check your own torque wrenches for accuracy.

  • Displays multiple units so you do not need multiple torque wrenches for metric applications.

  • Has a broader usage range than conventional torque wrenches (10-100% of range rather than 20-100%).


Meter layout

METER LAYOUT


Ts 1000 electronic torque meter

This is an overview of the key functions.


Quick start

QUICK START

1. Turn meter off

2. Plug in transducer

3. Turn meter on

4. Apply torque with transducer

Clears torque on the display

Saves torque on display


If you get stuck

IF YOU GET STUCK….

  • If you get stuck, the first thing to do is press the “clear” key.

  • If that does not get you back to operation mode then turn the meter off and back on again. The meter will turn back on in the mode and settings that were previously set.


Sleep mode

SLEEP MODE

The display will look like this when the meter goes into the battery saving-power down mode.

Press the “clear” key to wake the meter up


Modes of operation

MODES OF OPERATION

There are three display modes to choose from:

  • PEAK MODE

    • The display holds the highest torque until cleared.

  • FIRST PEAK MODE

    • This mode is used to capture the click point of a micrometer (clicker) torque wrench or screwdriver (used to test and calibrate torque wrenches).

  • TRACK MODE

    • The display tracks torque and down as it is applied.


Selecting the mode of operation mode key

SELECTING THE MODE OF OPERATION (MODE KEY)

  • Peak mode is the most common mode to operate in.

  • To get to peak mode press the “mode” key until the display shows ‘Peak.’

  • Press the “save” key to save the new mode.

Set-up

F

Peak

Saves mode

Selects mode


Units

UNITS

  • There are 6 different torque units that can be quickly selected with the “units” button:

Ft.lb.

N.m

dN.m

In.lb.

cN.m

In.oz.

Each transducer can read in the corresponding unitsso there is no need to buy different Metric or American transducers.


Changing units

CHANGING UNITS

  • Press the “units” button until the desired units show.

Setup

  • Press “save” button to store new units.


Target torque

TARGET TORQUE

  • You can quickly set a target torque with Go/No go limits.

The limit values can be set as a % of a target torquefor example, 4% of 100 ft.lb.

Or they can be set as actual high and low values for example, 96 ft.lb. to 104 ft.lb.

The type of tolerance used depends on how you set up the meter under Menu (default is % of the target torque)


Limits

LIMITS

SETTING LIMITS

Tolerance is set to 4%

Target torque is 100 ft.lb.

Press the “limits” key once

04

%

100.0

To turn on the limits function

RED Light turns on when torque is over 104 ft.lb.

GREEN light turns on when torque is between 96 and 104 ft.lb.

YELLOW light turns on when torque is under 96 ft.lb.


Setting a new target

SETTING A NEW TARGET

Press and hold the “limits” key for 1 second to set a new target torque.


Ts 1000 electronic torque meter

SETTING A TARGET TORQUE

  • Hold “limits” key for 1 second to set a new target torque value.

See next slide for instructions


Ts 1000 electronic torque meter

After pressing and holding the “limits” key the current target torque will show. You can now quickly set the new target torque value.

Here is how you set the value to 100.0

  • Increase the blinking digit with “increase” key

  • Go to next digit with “next” key

  • Press “save” key when finished


Zeroing the display

ZEROING THE DISPLAY

Make a habit of zeroing the display, even when the display shows “zero”

  • Press the “increase” and “next” keys at the same time to zero/tare the display.

Make sure there is no torque on the transducer when pressing the zero/tare keys.


To view the attached transducer information

TO VIEW THE ATTACHED TRANSDUCER INFORMATION

  • Press “limits” and “recall” at the same time to view the range of the attached transducers

Press “clear” key when finished viewing

Range (50 in.lb.)

Units

Cal factor (millivolts/volt)


Menu functions

MENU FUNCTIONS

There are 7 more advanced features under ‘Set-up Menu.’

  • 7 Menu functions are:

    • Recall Memory (Recall)

    • Send Memory (Send)

    • Erase Memory (Erase)

    • Display reset method

    • Limits method (% or high low)

    • Change Filters (Filter)

    • Calibration (Cal)


Selecting menu set up functions see manual for details

SELECTING MENU SET-UP FUNCTIONS(see manual for details)

Recall Memory

Press “mode” and “units”to enter menu set-up

Send Memory

Press “save” to select shown set-up option

Erase Memory

Set Filters

Set Tolerance type (% or Hi/lo)

Press “clear” to exit

Auto Reset method

The display will look like this

Press “next” key to scroll throughset-up functions

Calibration (CAL)


1 st option under set up recall

1ST OPTION UNDER SET-UP:RECALL

This function recalls the values in memory for you to view

After pressing “save” from menu location ‘Recall’ you will see this on display

This is the current number of values stored in memory

Press “next” key toscroll through memory

Torque Value

Data number

Units

Press “clear” when finished


2 nd option under set up menu send

2ND OPTION UNDER SET-UP MENU: SEND

This mode sends all values in memory out the RS232 serial port for printing or sending to a computer.

As the data is sent the data number will count on the LCD

See operation manual and Tech Tips for information on how to setup your printer or computer.


Ts 1000 electronic torque meter

3RD OPTION UNDER SET-UP MENU: ERASE

This function erases all torque data saved in memory

From Set-up press “save” when Erase is displayed

Press “save” again to erase

Or

Press “clear” to abort erase and return to operation


4 th option under set up menu filters

4TH OPTION UNDER SET-UP MENU: FILTERS

  • This is an option for setting filters. “500” Hz is common.

    (See the manual for a more detailed description on filters).

Press “next” to select a new filter

Press “save” to save the filter setting


5 th option under set up menu tolerance

5TH OPTION UNDER SET-UP MENU: TOLERANCE

This function will pre-set the default tolerance mode

You can choose between % of target or High and Low

Refer to the operation manual for details on how to set the default tolerance mode


Ts 1000 electronic torque meter

6TH OPTION UNDER SET-UP MENU: LCD RESET METHOD

This option sets up how you want the LCD to clear the torque value on the display during operation

Auto Reset

ManualReset

TimedReset

Saves new Reset method

See operation manual for a full description of reset methods


7 th option under set up menu cal

7TH OPTION UNDER SET-UP MENU: CAL

  • Cal is used to manually calibrate transducers. DO NOT select this mode unless you are familiar with the calibration procedures as stated in the manual.

If you select this mode accidentally, turn the meter off, then on again to get out of calibration mode without changing calibration factors.


Refer to operation manual for a full description of how to operate this meter

Refer to operation manual for a full description of how to operate this meter

That is it! You can see that this torque meter is very powerful, easy to learn and use.


How to order

1. Order one TS-1000 kit

Includes:

Torque meter

110 volt charger

9 volt Nicd battery

Serial output cable

Manual

Blow molded carrying case with bail handle

2. Order the transducer type and range(s) you need.

HOW TO ORDER:


Ts 1000 electronic torque meter

Safety Warnings:

  • Always use the proper range transducer for the application. Over torque may result in damage to the transducer or breakage, resulting in personal injury. Under torque may result in an incorrectly tightened fastener that could loosen, resulting in failure at a later date.

  • Never mount a transducer to a bench that is unstable or will tip when a torque is applied.

  • Always replace worn or rounded fasteners prior to applying torque. Slippage may occur resulting in personal injury.

  • Never try to recharge a non rechargeable battery.

  • Do not use a transducer if it has been over-torqued.

  • Never apply torque in a situation where tool breakage may result in a fall or slip resulting in personal injury. Pulling on the wrench, as opposed to pushing on the wrench may help avoid this situation.

  • Always wear safety glasses when operating this torque meter.


  • Login