An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Scout Pro Proven Durability

  2. The Ohaus Scout Pro • Scout Pro Portable Balance: • 7 Models From 200g x.01g to 6000g x 1g • 5 Application Modes • Optional USB or RS232 Interface Accessory w/cable • Density/Specific Gravity Determination with Below Balance Hook • Battery or AC Power (Power Pack Included) • Integral Security Bracket • Programmable Energy Saving Auto Shut-off

  3. The Ohaus Scout Pro • Scout Pro Versus the Competition

  4. The Ohaus Scout Pro • Scout Pro Versus the Competition

  5. The Ohaus Scout Pro • Added Capacity – 66% More!! • 2,000g X 0.1g model replaces the 1,200g X 0.1g model • More Application Modes -- • Counting is with APW recalculation • Percentage Mode -- Shows sample as % of reference weight • Totalization Mode -- Allows summation of sample weights • Display Hold Mode -- Holds last stable weight on display after sample is removed

  6. The Ohaus Scout Pro • Weighing Units -- • Kg, Lb and combined Lb:Oz units:

  7. The Ohaus Scout Pro • Connectivity is An Accessory -- • RS232 is an accessory which can be installed after purchase by the dealer or by the end user • Scout Pro offers an USB port also as an accessory • Both RS232 and USB ports come with an integral cable -- there is no extra cost for PC cable! • To connect to a printer (such as our SF42), a 9-pin to 25-pin converter cable is still required

  8. The Ohaus Scout Pro • Connectivity is An Accessory -- USB RS232

  9. The Ohaus Scout Pro • Easy-to-Read Display -- • 6 digits instead of 5 digits, with a higher-contrast LCD • Better Battery Performance -- • 4 “AA” Batteries give 30 hours battery life • Integral Shipping Lock -- • Each Scout Pro comes with a built-in shipping lock Battery Power Shipping Lock

  10. The Ohaus Scout Pro • Lockswitch -- • In LFT model, allows lock-out of calibration • In all models, locks current modes and units so they cannot be changed by operator • Integral Weigh-Below Hook -- • Scout Pro has a built-in weigh-below hook, which cannot be lost like the Scout II’s Lockswitch Weigh-Below Hook

  11. The Ohaus Scout Pro • Mode Overview: • Counting is with APW recalculation • Percentage Mode -- Shows sample as % of reference weight • Totalization Mode -- Allows summation of sample weights • Display Hold Mode -- Holds last stable weight on display after sample is removed Σ Totalization 0.00 Display Hold

  12. The Ohaus Scout Pro • Enhanced Parts Counting • APW Enhancement -- • The Scout Pro allows the user to turn-on automatic recalculation of the average piece weight (APW Optimization) -- this is the same function as found in Trooper Count and Ranger Count • Without Optimization, the APW is the average of the weight of the sample, divided by the number of pieces in the sample -- if the user needs a sample of 100, they have to count by hand 100 pieces! • With Optimization, the APW is the average of the weight of the initial sample as well as any subsequent samples -- the user can reach a sample of 100 by adding parts on the pan 10 at a time, increasing accuracy!

  13. The Ohaus Scout Pro • Enhanced Parts Counting • APW Enhancement -- • APW Enhancement is turned-on in the Units Menu by selecting “Cnt.Enh” -- it can be turned-off by selecting “Count” • The Scout Pro will recalculate the APW as long as two criteria are met: • The weight of the new sample is less than or equal to the weight currently on the pan -- if it is more, the Scout Pro will not perform an APW recalculation • The weight and platform are stable • Sample Sizes -- • The Scout Pro allows the user to change the sample size with a press of the Print/Unit key

  14. The Ohaus Scout Pro • Enhanced Parts Counting • This mode is enabled by turning-on the PC unit in the Units Menu • To use mode: • Press and hold Print/Unit key until “PC” is indicated • Display will then show “Clr.APu” • Press Print/Units to use target weight in memory (if there is one) • To enter a new sample, press On/Zero/Off once • Scout Pro will display “Put 10” • To select a different sample size, press Print/Unit • Place target weight on pan, press On/Zero/Off again • Scout Pro will display number of pieces in sample • To reset APW, press Print/Unit until “PC” is displayed again

  15. The Ohaus Scout Pro • Percentage Weighing • This mode allows the user to display the weight of a sample as a percentage of a reference weight • The reference weight is placed on the pan first, and equals 100% • Each reference weight will be a percentage from 0.1% to 99,999.9%, depending on the Capacity X Readability of the scale -- most users will use 1.0% to 200.0% at the most • Applications: Formulation and compounding, weight checking

  16. The Ohaus Scout Pro • Percentage Weighing • This mode is enabled by turning-on the “%” unit in the Units Menu • To use mode: • Press and hold Print/Unit key until “%” is indicated • Display will then show “Clr.Ref” • Press Print/Units to use target weight in memory (if there is one) • To enter a new target weight, press On/Zero/Off once • Scout Pro will display “Put.rEF” • Place target weight on pan, press On/Zero/Off again -- Scout Pro will display target weight • Press On/Zero/Off again -- Scout Pro will display 100% • To reset target weight, press Print/Unit until “%” is displayed again

  17. The Ohaus Scout Pro • Totalization • This mode allows the user to sum a series of weights -- up to the limit of the display (999,999) • Totalization can work with any weighing unit or mode -- including % or parts counting -- except Display Hold • Once you are in Totalization, you cannot change weighing units/modes without exiting Totalization • The Scout Pro will show the current measurement on the pan with a solid “t”, and then the total as a flashing “t” • Applications: Formulation and compounding, parts kitting Σ Totalization

  18. The Ohaus Scout Pro • Totalization • This mode is enabled by selecting “totAL” in the “MOde” part of the “S.E.t.U.P” menu • To set-up mode: • Enter Menu Mode, go to “S.E.t.U.P” and press Print/Unit until “MOde”is displayed -- Press “On/Zero/Off” key, and then press Print/Unit until “totAL” is displayed • Press On/Zero/Off to accept, then exit Menu mode • If the desired weighing unit is not shown, hold down Print/Unit to select now -- units cannot be changed once Totalization is started! Σ Totalization

  19. The Ohaus Scout Pro • Totalization • To Use Mode: • Place first weigh on pan, press Print/Unit once • Display will show current weight on pan with flashing “t” • Take weight of pan -- “t” will stop flashing, and weight will be 0 • Place another weight on pan, current weight will be displayed with solid “t” and unit • Press Print/Unit once • Display will show totalized weight in memory with flashing “t” • Repeat as required • To Exit Mode: • Hold “On/Zero/Off” down until “tOt.Off” is displayed Σ Totalization

  20. The Ohaus Scout Pro • Display Hold • This mode allows the user to hold the highest stable weight on the display until manually cleared • Display Hold can work with any weighing unit or mode -- including % or parts counting -- except Totalization • The Scout Pro will show the current measurement on the pan with a flashing stability indicator “*” • Applications: Postal and shipping 0.00 Display Hold

  21. The Ohaus Scout Pro • Display Hold • This mode is enabled by selecting “HoLd” in the “MOde” part of the “S.E.t.U.P” menu • To set-up mode: • Enter Menu Mode, go to “S.E.t.U.P” and press Print/Unit until “MOde”is displayed -- Press “On/Zero/Off” key, and then press Print/Unit until “HoLd” is displayed • Press On/Zero/Off to accept, then exit Menu mode • If the desired weighing unit is not shown, hold down Print/Unit to select 0.00 Display Hold

  22. The Ohaus Scout Pro • Display Hold • To Use Mode: • Place weight on pan, press Print/Unit once • Display will show “HoLd”, then current weight on pan with flashing “*” • Take weight of pan -- the display will remain with the flashing “*” • To Clear Display: • Press On/Zero/Off • To Exit Mode: • Enter Menu Mode, then “S.E.t.U.P”, enter “MOde”, and select “Off” • Press On/Zero/Off to accept, then exit Menu mode 0.00 Display Hold

  23. The Ohaus Scout Pro • Mode Recap: • Counting is enhanced with APW recalculation • Percentage Mode -- Shows sample as % of reference weight -- use for checkweighing, parts checking, formulation and compounding • Totalization Mode -- Allows summation of sample weights up to limit of display, not only capacity of scale -- Use for formulation, compounding, even for counting applications • Display Hold Mode -- Holds last stable weight on display after sample is removed -- Use for postal or shipping applications Σ Totalization 0.00 Display Hold

  24. The Ohaus Scout Pro • Scout Pro Unique Selling Points • Mechanical overload and shock load protection • Protects weighing cell 4 times better than Scout II • Simple 2-button operation – 5 applications and 7 weighing units • Optional USB or RS232 interfaces, simply insert the module; cable included