Fresenius medical care peritoneal dialysis connections
This presentation is the property of its rightful owner.
Sponsored Links
1 / 12

Fresenius Medical Care Peritoneal Dialysis Connections PowerPoint PPT Presentation


  • 183 Views
  • Uploaded on
  • Presentation posted in: General

Fresenius Medical Care Peritoneal Dialysis Connections. stay  safe to Baxter Connection. Connections using Fresenius Medical Care products.

Download Presentation

Fresenius Medical Care Peritoneal Dialysis Connections

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Fresenius medical care peritoneal dialysis connections

Fresenius Medical Care Peritoneal Dialysis Connections

staysafe to Baxter Connection


Connections using fresenius medical care products

Connections using Fresenius Medical Care products

This inservice is not intended to replace the advice or training from your physician. Refer to the Instructions For Use (IFU) for detailed device description, instructions, contraindications, warnings, and precautions.

Fresenius Medical Care, DEL-CLAMP, Stay●Safe, Safe-Lock, DELFLEX and FREEDOM are trademarks of Fresenius Medical Care Holdings Inc. or its affiliated companies. All other trademarks are the property of their respective owners.


Fresenius products

Fresenius Products

Baxter is a trademark of Baxter International Inc. or its affiliates.

Instructions on how to use Baxter products were reproduced from the manufacturer’s literature and were current at the time of print. Instructions are included for the patient's convenience but Fresenius Medical Care North America does not specifically endorse the use of these products or assume any liability related to their use. Should there be any differences between the instructions listed in this manual and the instructions for use provided with the medical devices referenced, the instructions provided with the medical device should be taken as accurate."


Connections using fresenius medical care products1

Connections using Fresenius Medical Care products

Note: for clarity the model is shown not wearing personal protective equipment (PPE). Follow your facility’s policies and procedures for use of personal protective equipment.

It is vital to maintain sterility of the connectors during connection procedures.


Stay safe patient to baxter supplies

staysafe patient to Baxter supplies

A staysafe Luer-Lock adapter, 4 inch will allow the patient with a Fresenius staysafe PD system to use Baxter supplies while in the hospital.

staysafe Luer-Lock adapter, 4 inch

Fresenius staysafePD system

Baxter supplies


Stay safe patient to baxter supplies1

staysafe patient to Baxter supplies

Gather supplies

staysafe Luer-Lock adapter, 4 inch (P/N #050-95003)

Baxter tubing solution set and related supplies for transfer set connection and exchange procedure.

Baxter extension set


Stay safe patient to baxter supplies2

staysafe patient to Baxter supplies

Adapter

  • Remove the cap from the patient’s extension set.

Patient extension set

1

2. Remove the sterility

cap from the larger

end of the adapter.

2

3. Attach the adapter to the extension set.

3


Stay safe patient to baxter supplies3

staysafe patient to Baxter supplies

4. While holding adapter, grasp the Baxter pull tab from the extension set sterility protector cap, pull to remove.

4

5

5. Remove the protector cap from the end of the staysafe luer-lock adapter.

6. Connect the Baxter extension set to the adapter. Proceed with the exchange following facility procedure.

6


Discharge instructions for all connections

DISCHARGE INSTRUCTIONSFOR ALL CONNECTIONS

  • The patient should return to his/her home or clinic with the additional extension in place. This practice will allow the patient to return home and resume dialysis without interruption.

  • Instruct the patient to remove any adaptors added to their extension set at the beginning of the next exchange or as directed by the PD clinic nurse.


Fresenius medical care peritoneal dialysis connections

Choose the type of catheter or transfer set and the type of system utilized. Look down the column and across the row to the adapter needed. Click on the icon in the box to take you to the procedure


Fresenius medical care peritoneal dialysis connections

Please contact your Fresenius Clinical Sales Representative at

1-800-662-1237 if you have questions regarding the use of a Fresenius PD system or adapter.


Fresenius medical care peritoneal dialysis connections

CD Available through Customer Service