1 / 23

Basics of Light and Lighting

Basics of Light and Lighting. What is light?. Light and radiation Light is a form of energy manifesting itself as electromagnetic radiation and is closely related to other forms of electromagnetic radiation such as radio waves, radar, microwaves, infrared and ultraviolet radiation and X-rays.

bell
Download Presentation

Basics of Light and Lighting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Basics of Light and Lighting Lighting concepts

  2. What is light? Light and radiation Light is a form of energy manifesting itself as electromagnetic radiation and is closely related to other forms of electromagnetic radiation such as radio waves, radar, microwaves, infrared and ultraviolet radiation and X-rays. Light is the electromagnetic radiation that the human eye perceives as brightness, in other words the part of the spectrum that can be seen. This is the radiation between 380 and 780 nanometres (nm), a tiny fraction of the known spectrum of electromagnetic radiation. Lighting concepts

  3. Basic parameters used in lighting Luminous flux (F) Unit of measurement: lumen (lm) All the radiated power emitted by a light source and perceived by the eye is called luminous flux (F). • 75W incandescent lamp: 900 lm • 39W fluorescent lamp: 3.500 lm • 250W high pressure sodium lamp: 30.000 lm • 2000W metal halide lamp: 200.000 lm Luminous intensity (I) Unit of measurement: candela (cd) Generally speaking, a light source emits its luminous flux (F) in different directions and at different intensities. The visible radiant intensity in a particular direction is called luminous intensity (I). Examples (centre of beam): • 5W bicycle lamp without reflector: 2,5 cd • 5W bicycle lamp with reflector: 250 cd • 120W incandescent reflector lamp: 10.000 cd • Lighthouse: 2.000.000 cd Lighting concepts

  4. Basic parameters used in lighting Luminance(L) Unit of measurement: cd / sqm Luminance is the only basic lighting parameter that is perceived by the eye. It specifies the brightness of a surface and is essentially dependent on its reflectance (finish and colour). Examples: • Surface of the sun: 1.650.000.000 cd/m2 • Filament of a clear incandescent lamp: 7.000.000 cd/m2 • Fluorescent lamp: 5000-15.000 cd/m2 • Road surface under artificial lighting: 0,5-2 cd/m2 Illuminance (E) Unit of measurement: lux (lx) Illuminance (E) is a measure of the amount of light falling on a surface. It is influenced by the distance the light source is away from the area being illuminated. An illuminance of 1 lux occurs when a luminous flux of 1 lumen is evenly distributed over an area of 1 square metre. Examples: • Summer, at noon, under a clear sky (equator): 100.000 lux • In the open under a heavily-overcast sky: 5.000 lux • Artificial light, in a well-lit office: 800 lux • Full moon, on a clear night: 0,25 lux Lighting concepts

  5. Basic parameters used in lighting Luminous efficacy Unit of measurement: lumens per watt (lm/W) Luminous efficacy indicates the efficiency with which the electrical power consumed is converted into light. Luminaire efficiency Luminaire efficiency (also known as the light output ratio) is an important criterion in gauging the energy efficiency of a luminaire. This is the ratio between the luminous flux emitted by the luminaire and the luminous flux of the lamp (or lamps) installed in the luminaire. Lighting concepts

  6. Basic parameters used in lighting Lamp Life Because of slight variations in lamp materials and manufacturing operations, lifetimes of individual lamps differ. The term ‘lamp life’ usually refers to the ‘average rated life’ of a lamp. This is the time after which, on statistical average, half (50%) of a ‘not too small’ number of lamps fail in a controlled operating environment. Each of the lamps in the test group should be of the same wattage, voltage and construction. Lighting concepts

  7. Basic parameters used in lighting Colour Appearance & Colour Rendering Light sources have two different colour properties related to the spectral composition of their emission. One is the apparent colour of the light that the source emits and the other is the effect that the light has on the colours of surfaces. The latter is called colour rendering. When a light source is being chosen, both the colour appearance and the colour-rendering properties of the source should be considered in addition to its efficacy and life. Lighting concepts

  8. Basic parameters used in lighting Colour Appearance The colour appearance of near white light sources is normally defined in terms of their correlated colour temperature (CCT), expressed in kelvin (K). The higher the correlated colour temperature the cooler the appearance of the light source. An ordinary incandescent lamp, for example, has a colour temperature of 2800K, whereas a daylight fluorescent lamp can have a colour temperature of 6000K. Figure 1: The CIE Chromaticity Diagram The International Commission on Illumination (CIE) has grouped lamps into three classes of correlated colour temperatures Lighting concepts

  9. Basic parameters used in lighting Colour rendering The CIE general colour-rendering index is a measure, on a scale of up to 100, of the correspondence between the colour of an object (its “self luminous colour”) and its appearance under the nearest reference light source. A light source with an Ra value of 100 displays all 14 test colours exactly as they appear under the reference light source. The lower the Ra value, the worse the colours are rendered. The CIE general colour-rendering index (CRI) is the most widely accepted measure of the colour rendering properties of a light source. Initial Illuminance Initial illuminance is defined as the value of average illuminance which is initially provided by the lighting system, i.e. with new lamps (aged to 100 hours), clean luminaires and room surfaces. Lighting concepts

  10. Maintenance factor Maintenance illuminance is defined as the average illuminance below which it is necessary to take remedial action in terms of maintaining the lighting system, eg. by replacing the lamps or by cleaning the luminaires, windows, rooflights and room surfaces. The lighting scheme should be designed with an overall maintenance factor (MF) calculated for the selected lighting equipment, environment and specified maintenance schedule. The recommended illuminance for each task is given as maintained illuminance. The maintenance factor depends on the maintenance characteristics of the lamp and control gear, the luminaire, the environment and the maintenance programme. Lighting concepts

  11. The illuminance • The illuminance and its distribution on the task area and on the surrounding area have a great impact on how quickly, safely and comfortably a person perceives and carries out the visual task. • Scale of illuminance • To give a perceptual difference the recommended steps of illuminance (in lx) are according to EN 12665: • 20 - 30 - 50 - 75 - 100 - 150 - 200 - 300 - 500 - 750 - 1 000 - 1 500 - 2 000 - 3 000 - 5 000 • The required maintained illuminance should be increased when: • visual work is critical; • errors are costly to rectify; • accuracy, higher productivity or increased concentration is of great importance; • task details are of unusually small size or low contrast; • the task is undertaken for an unusually long time; Lighting concepts

  12. The illuminance • The required maintained illuminance may be decreased when: • task details are of an unusually large size or high contrast; • the task is undertaken for an unusually short time. Key 1- task area 2 -immediate surrounding (band with a width of at least 0,5 m around the task area within the visual field) 3 -background area (at least 3 m wide adjacent to the immediate surrounding area within the limits of the space) Minimum dimensions of immediate surrounding and background area in relation to task area Lighting concepts

  13. The illuminance Relationship of illuminances on immediate surrounding to the illuminance on the task area Measuring level for task area of the workplaces is at 0.75m above floor level ! Lighting concepts

  14. Glare Glare is the sensation produced by bright areas within the visual field, such as lit surfaces, parts of the luminaires, windows and/or roof lights. Glare shall be limited to avoid errors, fatigue and accidents. Glare can be experienced either as discomfort glare or as disability glare. Discomfort glare UGR – stands for Unified Glare Rating The recommended limiting values of the UGR : 10, 13, 16, 19, 22, 25, 28 Lighting concepts

  15. Electric measuring units Volt The Volt (V) is the unit of measurement stabilised by the International System of Measurement for quantifying differences in electrical potential. It is defined as the potential difference existing between the extremes of one conductor in which power of 1 watt is released when current equal to 1 ampere is fluxing inside. Watt The Watt (W) is the unit of measurement of energetic flux and represents the power emitted, transported or received in the form of radiation. Ampere The Ampere(A) is the unit of electric current. P(power) (Watt) = U(voltage)(volts) x I( current)(amps) x cosØ Lighting concepts

  16. Terms and definitions • Activity area - area within which a specific activity is carried out • Background area - area adjacent to the immediate surrounding area • Immediate surrounding area - band surrounding the task area within the visual field • Roof light - daylight opening in the roof or a horizontal surface of a building • Shielding angle - angle between the horizontal plane and the first line of sight at which the luminous parts of the lamps in the • luminaire are directly visible • Task area - area within which the visual task is carried out • Visual task - visual elements of the activity undertaken • Work station - combination and spatial arrangement of work equipment, surrounded by the work environment under the conditions imposed by the work tasks Lighting concepts

  17. Luminous environment • Lighting requirements are determined by the satisfaction of three basic human needs: • visual comfort, where the workers have a feeling of well-being; in an indirect way this also contributes to a higher productivity level and a higher quality of work; • visual performance, where the workers are able to perform their visual tasks, even under difficult circumstances and during longer periods; • safety Lighting concepts

  18. Lighting requirements for interior areas, tasks and activities Lighting concepts

  19. Lighting requirements for interior areas, tasks and activities Lighting concepts

  20. Lighting requirements for interior areas, tasks and activities Lighting concepts

  21. Lighting requirements for interior areas, tasks and activities Lighting concepts

  22. Lighting requirements for interior areas, tasks and activities Lighting concepts

  23. Lighting concepts

More Related