Welcome to bch electric limited
This presentation is the property of its rightful owner.
Sponsored Links
1 / 6

Air Circuit Breakers PowerPoint PPT Presentation


BCH Electric Limited is committed to achieve a leadership position in the electrical switchgear, control gear and automation industry by creating a technical and marketing advantage to consistently meet and exceed customer expectations.

Download Presentation

Air Circuit Breakers

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Welcome to bch electric limited

WelcometoBCH ELECTRIC LIMITED

www.bchindia.com


Air circuit breakers

Air Circuit Breakers

The unique “Double Break” main contact system ensures extremely fast interruption of short circuit currents and substantially reduces main contact wear. The internally symmetrical “Double Break” structure allow reverse power connection. This is the only ACB with this facility in India

Very fast interruption by Double Break system


No extra arc space required vertical stacking permitted

No extra arc space required, vertical stacking permitted

No extra arc space

The TemPower2 ACB dissipates all arc energy within its unique

“Double Break”

arc chamber. This internal energy dissipation  allows the clearance distance between  the ACB  and  nearby earthed metal to be zero  minimizing switchboard height and costs.

Releases


Tempower2 provides positive protection for electric power systems

TemPower2 provides positive protection for electric power systems.

The TemPower2 series comes equipped with  RMS sensing over-current releases (OCR) offering a wide range of protection functions and capabilities.


Air circuit breakers

* L-Characteristic general feeder circuits protection * R- Characteristics general feeder circuits protection * Generator  protection

Protection features

Standard

* Long time delay

* Short time delay

* Instantaneous (Optional)

* Ground fault

* Reverse Power trip

* N-phase protection

* Earth leakage

* Two channel pre trip

* Advance LCD display

* Contact temperature monitoring

* Communication protocol

TemPower2 Air Circuit Breakers

Double Break System : Two Steps ahead


Contact us

TOLL FREE : 1800-103-9262

Fax : 91 11 23715249

CORPORATE OFFICE : 

1105,New Delhi House,27,Barakhamba Road,

New Delhi - 110 001

91 11 23316029 / 3610 / 6539,

[email protected]

CONTACT US :-

Thank You

www.bchindia.com


  • Login