html5-img
1 / 8

Gasfuse™ South Africa

Business Overview. GasFuse™ South Africa Ltd is the appointed Key Master Distributor of GasFuse™ for and on behalf of Premier Fosters Australia Pty Ltd for Southern Africa.

basil-nash
Download Presentation

Gasfuse™ South Africa

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Business Overview GasFuse™ South Africa Ltdis the appointed Key Master Distributor of GasFuse™for and on behalf of Premier Fosters Australia Pty Ltd for Southern Africa. Moreover, Premier Fosters Australia Pty Ltd have met all the Australian Gas Association procedures and compliance to ensure conformance to the regulations and standards of the Australian Gas Association, Australian Gas Association Approval Number 6127, Patent No.597625. GasFuse™ South Africa Ltd, is a Company, located within Gauteng, South Africa. The Core Nature of the Business is to Import, Supply & Distribute Sophisticated Liquid Petroleum Gas Safety Equipment. An official Business Module outlining Products and Services to be supplied and distributed will be promoted byGasFuse™ South Africa Ltd to prospective and existing Channel Partners. Marketing material and/or electronic format brochures as well as intellectual features and functions of GasFuse™ are accessible on our Worldwide Webpage to approved Channel Partner/s. GasFuse™ South Africa Ltdoffers you an opportunity to diversify your services and products, increase your market share and expand your operations even further by marketing our exclusive GasFuse™ LPG Safety Product. Gasfuse™ South Africa

  2. The Sequence of Normal Gas Flow Gas enters the Gasfuse directly from the cylinder; Gas is channeled into a chamber, where it passes the shutoff element; Gas is then channeled up out of the chamber and past the gauge pin; Gas then exits; The various uses of Gasfuse all follow from this sequence. Importantly, the gauge pin is directly attached to the gauge, and acts as a pressure detector, which causes the gauge to show changes in gas pressure via movement in the needle. Sequence of normal Gas Flow

  3. How Gasfuse™ Stops Major Leaks The shutoff mechanism works on the Bernouilli effect. A sudden increase in gas flow (for example from the hose rupturing) changes the pressure around the shut off element, lifting it up and causing it to plug the exit to the chamber and stop the flow of gas completely. The shutoff element will stay in this position until you push down on the gauge. The gauge pin then pushes the shutoff element back down into the chamber, so resetting the Gasfuse ready for normal operation. How Gasfuse™ Detects Small Leaks By turning the cylinder on and the appliance off, you allow gas to fill the Gasfuse, gas hose and all gas pipes and manifolds, all the way up to the appliance. When you turn the gas cylinder off, the gas should stay in the Gasfuse, hose and inside the appliance. If there is any leak, the pressure should drop because gas is escaping but not being replenished (because the cylinder is off). The drop in pressure will be detected by the gauge pin, causing the needle to move downwards. How Gasfuse™ Tells You That You're Low On Gas The gauge detects pressure through the gauge pin. When gas in the cylinder is low, the pressure drops and the needle falls towards the red section of the gauge. Gasfuse™ Principle Functions

  4. Australian Standard AS4557-2004 By law, all new barbecues sold in Australia must have a device fitted which either shuts off or limits the flow of gas.. (Implementation date 1 January 2005, clause 2.4.1.2). The actual wording of the clause is: Means to automatically shut off or reduce gas flow that will operate at a flow of not more than 3.0 cu.m/hr (air equivalent at standard conditions) with 700 kPa supplied to the inlet of the device. In the case of a device that reduces the flow of gas, the bypass shall not allow a flow greater than 0.3 m3/h (air equivalent at standard conditions) with 700 kPa supplied to the inlet of the device.The means shall-(a) be integral with the regulator assembly;(b) be designed in a way to prevent consumer disassembly without the use of specialized tools or undue force; and(c) include either manual or automatic reset without the need to disconnect any part of the gas piping system, including the cylinder connection. This clause recognises that gas safety is a more serious issue now than any time in the past. Gasfuse does more than meet the minimum requirement of the standard. It meets or exceeds the most most stringent requirement for total shutoff. The exact implementation date of this clause is under review. Gasfuse™ Gas Safety Standards

  5. AGA Certificate

  6. Geneve International Diploma

  7. Underwriters Laboratory Report

  8. Thank you We believe that a type of transaction/partnership between us would be mutually beneficial and fruitful. Your company has already tapped the local resident market and has its own Clientéle market share. GasFuse™ South Africa Ltdoffers you an opportunity to diversify your services and products, increase your market share and expand your operations even further by marketing our exclusive GasFuse™ LPG Safety Product. We look forward to our future collaboration and please do not hesitate to contact us if you need any additional information or have any queries. Respectfully;Keith VersterMobile:- +27 078-055-9330Email:- keith@gasfusesa.co.za Webpage:- www.gasfusesa.co.zaFor and on behalf of GasFuse™ South Africa Ltd Gasfuse™ South Africa

More Related