1 / 7

Preliminary result presented @KAON09

Preliminary result presented @KAON09. Preliminary result presented @KAON09. Roadmap to a definitive result :. Reduce statistical error : Extend fit region down to 6 ns (at least )  hide a bad control of the background

avidan
Download Presentation

Preliminary result presented @KAON09

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Preliminaryresultpresented @KAON09

  2. Preliminaryresultpresented @KAON09

  3. Roadmapto a definitive result : Reduce statisticalerror: Extendfitregiondown to 6 ns (at least)  hide a bad controlof the background Include 2004 data (0.7 fb-1 , smalleffectanyhow)  almostdone, needtotune some cuts, no big surprises Reduce systematics : Redotagsystematics  isactuallymuchsmaller ! New estimate ofnuclearinteractions  stillusing 2002. Not a big contribution, butmustbechecked Need some work. Connection withfitregion

  4. Tagsystematicswasevaluatedwrongly !!!!!! The variationof the slopewasdirectlyappliedto the resultobtainedwith the standard energythreshold. Instead, the analysisshouldhavebeenrepeated: in this way the effectismuchsmaller !!! We estimate that the tagefficiency can bereducedby at leastfactorof 2

  5. Fitregionhides a seriousproblem Fitveryunstable at smalltimes Assumeditdepends on the beam loss due to regeneration and nuclearinteraction on DC wall : Effect on propertimedistributionevaluatedanalytically: - beam loss on sphericalbeam pipe produce a step - cylindrical DC wallhas a complicatedeffect: at time t1one can feel or not the beam loss depending on kaonemission angle. Thishasalsotobeconvoluted withkaonangulardistribution. t1 New fitfunction: ( 1 – Ploss f(tdc/t*) ) + Plossnewparameter,tdcfixed

  6. New fitfunction far frombeingenough ! EitherPlossgoesvery high (expected 10-3 ÷ 10-4 ), eitherfBCKgoes up to 2 (was 0.74 in previousfit) Regeneration and nuclearinteractions background are reproducedverydifferently in MC at low and at high decaytimes. Needtofixitto data. This can also help re-estimating the nuclearinteractioncorrectiontotL. p+p-p0 background seems under control ?

  7. Up tonow the onlygoodvariabletoselectnuclearinteractionshasbeed the angle a :

More Related