An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Frederick Schwartz MS Graduate Student Room/Office: 1335 Email: fschwartz@wisc.edu From: Fort Atkinson, WI Undergraduate: ME, UW-Platteville ‘08 Thesis: Development of Predictive Correlations for Thermal-Fluid Behavior of Mixed Refrigerants (ASHRAE Project 1602)

  2. Experimental Significance • Mixed refrigerants have a thermodynamic advantage when compared to pure fluids for Joule-Thompson refrigeration cycles • Accurate prediction of thermal-fluid behavior is critical to design of cryogenic systems • No practical correlations currently exist for thermal-fluid behavior of mixed refrigerants at cryogenic temperatures for use in equipment design

  3. Test Facility Design ASHRAE Testing Requirements: • Six Refrigerant Concentrations • R14 (35% ), R23 (15% ), R32 (15% ), and R134a (35% ) • Diluted with Argon (0%, 20%, 40%) • Methane (45%) , Ethane (35%) , and Propane (20%) • Diluted with Nitrogen (0%, 20%, 40%) • Mass flux: 250 kg/m2-s • Heat flux: 10 kW/m2 • Temperatures: 150 K to room temperature • Pressures: 100kPa, 1000 kPa • Tube diameters: 0.5, 1.5, & 3.0 mm • Minimize convection and radiation heat transfer around test section Test Section Tout Tin Twall gas mixture

  4. Research Objectives • Obtain thermal-fluid behavior data from the ASHRAE specified test conditions using the test facility developed for this project • Develop predictive, semi-empirical correlations for use in refrigeration equipment design