An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Humidifiers for Every Application

  2. 2011 Factory Training Sales / Technical Training September 14 to 16, 2011 Service Training September 19 to 21, 2011 Register today! Spaces are limited!

  3. Nortec Warranty Department Effectively immediately please use warranty.nortec@waltermeier.com New E-mail Address

  4. NEW Links XPS • Launch in e-news • New part numbers • Installation manuals • Price pages Launch March 4

  5. NEW The Nortec RoadShow Hit The Road February 1 humidity.com

  6. Humidifiers for Every Application

  7. The MH Series

  8. Webinar Agenda Agenda Theory Applications MH Series Models Operation / Maintenance Control strategies

  9. The Science Behind Humidity • 1075 BTU/lb for water phase change (liquid to gas) • Isothermal (steam) humidifiers use electricity or gas • Adiabatic (evaporative) humidifiers draw energy from air Liquid Water Water Vapor(“Humidity”) ~1075 BTU/lb

  10. Adiabatic and the Psychometric Chart

  11. Temperature Drop Example: System CFM = 20,000 cfm Humidity load = 200 lbs/hr *Heat is removed at a rate of roughly 1075BTU’s/lb of water evaporated Formula: T = BTU CFM x 1.10 (Constant) T = 200 x 1075 BTU 20,000 CFM x 1.10  T = 9.8°F Cooling and humidity go hand in hand!

  12. Adiabatic: The “Sensible” Solution • Best Scenarios • Constant cooling load • Waste heat is available • Summer cooling / humidity • Regional applications

  13. Applications

  14. Applications: LEED Projects • Energy conscious (low kW) • Consider summer cooling • Humidity control • Synergies: EAp2, EAc1 EQc7, ID

  15. Nortec Adiabatic Systems HP HVAC MH Series AFE Nozzles

  16. Which Technology to Use?

  17. The MH Series

  18. MH Series: Features and Benefits • Low Energy Usage • Adiabatic Cooling • Complete Packaged Unit • Zero Absorption Distance • Rapid Assembly • Ideal for Retrofits

  19. MH Series: Principle of Operation Hot Dry Air Wet Media Pads Cool Humid Air

  20. MH Series: Principle of Operation or to Drain

  21. MH Series: Model Lineup

  22. Original MH Series: Components Water Hood Control Panel V-Profile Media Box Recirculation sump Stage Valves Inlet Valve Base Pan Drain Valve

  23. New MH Series: Components Connections Control panel Framework Recirculation Unit (Recirculation Models only) Base Pan Media Box

  24. MH Series Changes: Frame and Base Pan • 25% fewer fasteners • Easier media access • 80% weight reduction on metal • Clip in mist eliminator • Side connections (like SAM-e) • Reduced water volume • 17 inch duct footprint

  25. MH Series: Recirculation Components Stage Valves Inlet Valve UV Water Treatment Circulation pump Drain Valve Reservoir

  26. MH Series: Flow Through Components • Wall mounted • Staging valves • Flush valve • Easy installation

  27. MH Series: V-Profile Media Boxes • Polyester Media • V-groove profile • Hygroscopic profile • High efficiencies • Low pressure drops • UL 900 Class 1 (USA) • ULC-S111-07 Class 2 (CAN) • RO / DI / Potable water Thinking Inside the Box!

  28. MH Series: Pressure Drop 12 Inch Media 8 Inch Media

  29. MH Series: When to Change Media Based on 2200 hour seasons Inspect media regularly according to operating manual.

  30. 1. 2. MH Series: Media Replacement

  31. MH Series: Basic Controller • Flow through models only • Factory configured • LED status display • Internal diagnostics display • No user configuration • Automatic hygiene cycles

  32. MH Series: Total Controller Total Controller Advantage! • Smart water management • Advanced hygiene control • Backlit display • Modbus standard • BACnet / Lon optional • NRTL/C approvals

  33. MH Series: Operation Safety and Cleanliness • 2008 ASHRAE Handbook – HVAC Systems & Equipment S40.9

  34. Control Sequences

  35. MH Series: Whitepaper • Basics of evaporative media • Best applications • Benefits of polyester media • Best practices

  36. MH Series: Quotes • Quotes from factory • Provide basic info • 2 day turnaround • Complete submittal package

  37. MH Series: Summary • Complete packaged product • Accepts ALL water types • Models for any project • External recirculation unit • Advanced control systems • Low pressure drop • 0 absorption distance • Low energy use and cooling • Many great applications

  38. MH Series: Challenge

  39. MH Series: Questions?