Radon Mitigation using Ventilation Assessment Tool

Radon Mitigation using Ventilation Assessment Tool. Group 9 William Allred Joshua Chastain Daniel Diaz Ryan Nester. Introduction. Naturally occurring radioactive gas Colorless, tasteless, odorless Found all over the World Kills over 20,000 people each year (EPA).

ania
Download Presentation

Radon Mitigation using Ventilation Assessment Tool

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radon Mitigation using Ventilation Assessment Tool Group 9 William Allred Joshua Chastain Daniel Diaz Ryan Nester

  2. Introduction • Naturally occurring radioactive gas • Colorless, tasteless, odorless • Found all over the World • Kills over 20,000 people each year (EPA) Group 9 – Department of Health

  3. Introduction – What is the Problem? • High rise residential buildings also have Radon problems • Limited on mitigation techniques • Ventilation applicable to dilute Radon • Need methods to estimate airflow for dilution Group 9 – Department of Health

  4. Project Scope • Develop a spreadsheet tool to evaluate the parameters necessary for successful mitigation of a single unit within a multi-family structure using ventilation techniques. • Current radon level • Target radon level • Characteristics of unit • Volume of unit • Natural leakage to outside • Ventilation rate required to reach target Group 9 – Department of Health

  5. The Design Concept Group 9 – Department of Health Group 9 – Department of Health Group 9 – Department of Health

  6. Design Concept – How it Works • Equations / Theories • Where: • ELA = Equivalent Leakage Area • As = Floor Area • W = Weather Factor • V = Volume of unit • ACH = Estimated Annual Infiltration Rate • Co = Initial Concentration of Radon • G = Generation rate of Radon Group 9 – Department of Health

  7. Contaminant Equations Dilution Equation - Mass of Radon in zone i after a given time - Initial mass of Radon in zone i - Mass flow rate of Radon into zone i - Generation rate of Radon in zone i - Mass flow rate of Radon out of zone i Group 9 – Department of Health Group 9 – Department of Health

  8. Spreadsheet Demonstration Group 9 – Department of Health

  9. On-site Testing – Miami, FL • Blower Door Fan Tests • Leakages found from Pressurization and Depressurization tests • Smoke Sticks for airflow direction • Unexpected leakage sources Group 9 – Department of Health

  10. Spreadsheet Results – Loft 2 Group 9 – Department of Health

  11. Spreadsheet Results – Park Place by the Bay Group 9 – Department of Health

  12. Spreadsheet Results – Key Biscayne Group 9 – Department of Health

  13. Cost Analysis Group 9 – Department of Health

  14. Conclusion • Accuracy depends on construction methods • Other sources of error include unknown leakage values, data libraries, and blower door extrapolations • Spreadsheet gives a reasonable approximation of airflow required for mitigation • Serves as a foundation for future development in high-rise residential Radon mitigation Group 9 – Department of Health

  15. Future Improvements • Test wide variety of units • Test after mitigation • Implement correction factor • More weather data • Consider indoor leakages • More libraries Group 9 – Department of Health

  16. Acknowledgment • Special thanks to • Florida Department of Health • Clark Eldredge • Jorge Laguna • FAMU Institute of Building Sciences Director • Thomas Pugh • Faculty Advisor • Juan Ordoñez • Homeowners • Garmin Ranck • Daniel Montesinos • Nicholas Landera Group 9 – Department of Health

  17. References • Design of Fluid Thermal Systems William S. Janna • NIST Multizone Modeling Website (CONTAM) http://www.bfrl.nist.gov/IAQanalysis/index.htm • Minneapolis Blower Door Operations Manual The Energy Conservatory • Walton, George. “CONTAM 2.4 User Guide and Program Documentation.” http://www.bfrl.nist.gov/IAQanalysis/docs/NISTIR_7251c.pdf Group 9 – Department of Health