1 / 27

BBG 012

Loop Selection from MOD. EF biplane. EF a 3CV. WMA. EBD. Image Quality. UNENHANCED. BBG 012. Study -Echocardiography - Onsite Evaluations and Measurements. SonoVue. Loop Selection from MOD. EF biplane. EF a 3CV. WMA. EBD. Image Quality. CONTENTS.

anevay
Download Presentation

BBG 012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED BBG 012 Study -Echocardiography - Onsite Evaluations and Measurements SonoVue Loop Selection fromMOD EF biplane EF a 3CV WMA EBD Image Quality

  2. CONTENTS page Loop Selection from MOD - SonoVue 13/14 Loop / Page Overview - SonoVue 15 LV-Volumes / EF biplane a4-CV endsyst. 16/17 a4-CV enddiast. 18 a2-CV endsyst. 19 a2-CV enddiast. 20 LV-Volumes / a 3CV monoplane a4-CV endsyst. 21 a4-CV enddiast. 22 Wall Motion Analysis 23 EBD / Image Quality 24 Contrast Quality / Artifacts 24 page Loop Selection from MOD - unenhanced 1/2 Loop / Page Overview - unenhanced 3 LV-Volumes / EF biplane a4-CV endsyst. 4/5 a4-CV enddiast. 6 a2-CV endsyst. 7 a2-CV enddiast. 8 LV-Volumes / a 3CV monoplane a4-CV endsyst. 9 a4-CV enddiast. 10 Wall Motion Analysis 11 EBD / Image Quality 12

  3. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED Selection of acquired Loops from MOD (1) Touch 2D, Freeze and touch Loop 1 2 Touch Delete all pages to empty storage buffer, Touch Disk Retrieve 3 1

  4. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED Selection of acquired Loops from MOD (2) Select patient ---N( Native) (List All Studies) and confirm with o.k.(data loading takes approx. 5 min) 1 2 Touch Display, touch Preset, select BBG012 Native Touch Loop, touch Display, You can toggle through the loops/pages by turning the respective knob. For measurements of biplane EF start with page 1 from 8 (1/8), i.e. apical 4 CV unenhanced 3 2

  5. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED Loop/Page Overview - native Page 1 = a 4 CV Page 2 = a 2 CV Page 3 = a 3 CV Page 4 = SAX Page 5 = Colour Kinesis - a 4 CV Page 6 = Colour Kinesis - a 2 CV Page 7 = Colour Kinesis - a 3 CV Page 8 = Colour Kinesis - SAX 3

  6. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAs ap 4 - MOD) 1 Freeze Loop 1/ Page 1 Select a 4CV unenhanced endsystolic frame (by trackball) 2 Touch Analysis and EF & Volumes 3 Touch EF (MOD-bp) and LVAs ap 4 MOD Record all Measurements on SVHS Videotape 4

  7. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane (LVAs ap 4 - MOD) 1 Move cursor to position at endocardial border of basal septal segment on mitral valve insertion 2 Press Trace 3 Perform Tracking 4 Press Enter twice Print Out (for documentation of LV-Volumes) 5 6 Press Erase . 5

  8. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAd ap 4 - MOD) 1 Select enddiastolic frame (by trackball) 2 Touch LVAd ap 4 MOD Move cursor to position at endocardial border of basal septal segment on mitral valve plane. 3 Press Trace 4 5 Perform Tracking Press Enter twice 6 7 Print Out (for documentation of LV-Volumes) 8 Press Erase 6

  9. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAs ap 2 - MOD) 1 Touch Loop, touch Display, Go to page 2 from 8 (2/8) (a2CV) 2 Select endsystolic frame (by trackball) Touch LVAs ap 2 MOD 3 Move cursor to position at endocardial border of basal inferior segment on mitral valve plane. 4 5 Press Trace 6 Press Enter twice 7 Perform Tracking Print Out (for documentation of LV-Volumes) 8 Press Erase 9 7

  10. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAd ap 2 - MOD) 1 Select enddiasstolic frame (by trackball) Touch LVAd ap 2 MOD 2 Move cursor to position at endocardial border of basal inferor segment on mitral valve plane. 3 4 Press Trace 5 Perform Tracking 6 Deactivate Results Box 7 Press Enter twice Print Out (for documentation of LV-Volumes) 8 Touch Report + Print Out report 9 Insert derived volumes (--> see print outs) / EF (--> see report) from biplane and monoplane a4CV measurements into CRF-Page 15 10 8

  11. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF monoplane a3CV(LVAs ap 4 - MOD) 1 Touch Erase All and confirm with Enter Touch Loop, touch Display, Go to page 3 from 8 (3/8) (a3CV) 2 3 Select endsystolic frame (by trackball) 4 Touch Analysis and EF & Volumes 5 Touch EF (MOD-bp) and LVAs ap 4 MOD Move cursor to position at endocardial border of basal posterior segment on mitral valve plane. 6 10 Print Out (for documentation of LV-Volumes) 7 Press Trace and PerformTracking Press Erase 11 Press Enter twice 8 9

  12. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF monoplane a3CV(LVAd ap 4 - MOD) Select enddiasstolic frame (by trackball) 1 Touch LVAd ap 4 MOD 2 3 Move cursor to position at endocardial border of basal inferior segment on mitral valve plane. 4 Press Trace Perform Tracking 5 6 Deactivate Results Box 7 Press Enter twice 8 Print Out (for documentation of LV-Volumes) Touch Report + Print out Report 9 10 Insert derived volumes (--> see print outs) / EF (--> see report) from monoplane a3CV measurements into CRF-Page 15 10

  13. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED Wall Motion Analysis Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 Perform segmental WMA (16 segment model). CK (loops 5-8) may be used as additive information 2 11

  14. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality UNENHANCED Image Quality Endocardial Border Delineation Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 2 Perform segmental EBD (16 segment model). Assess overall image quality according to the score given on page 15 of the CRF 2 12

  15. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue Selection of acquired Loops from MOD (1) Touch 2D, Freeze and touch Loop 1 2 Touch Delete all pages to empty storage buffer, Touch Disk Retrieve 3 13

  16. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue Selection of acquired Loops from MOD (2) Select patient ---S ( SonoVue) (List All Studies) and confirm with o.k.(data loading takes approx. 5 min) 1 2 Touch Display, touch Preset, select BBG012 SonoVue Touch Loop, touch Display, You can toggle through the loops/pages by turning the respective knob. For measurements of biplane EF start with page 1 from 8 (1/8), i.e. apical 4 CV SonoVue 3 14

  17. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue Loop Overview - SonoVue Page 1 = a 4 CV Page 2 = a 2 CV Page 3 = a 3 CV Page 4 = SAX Page 5 = Colour Kinesis - a 4 CV Page 6 = Colour Kinesis - a 2 CV Page 7 = Colour Kinesis - a 3 CV Page 8 = Colour Kinesis - SAX 15

  18. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAs ap 4 - MOD) 1 Freeze Loop 1/ Page 1 Select a 4CV unenhanced endsystolic frame (by trackball) 2 Touch Analysis and EF & Volumes 3 Touch EF (MOD-bp) and LVAs ap 4 MOD Record all Measurements on SVHS Videotape 16

  19. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane (LVAs ap 4 - MOD) 1 Move cursor to position at endocardial border of basal septal segment on mitral valve insertion 2 Press Trace 3 Perform Tracking 4 Press Enter twice Print Out (for documentation of LV-Volumes) 5 6 Press Erase . 17

  20. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAd ap 4 - MOD) 1 Select enddiastolic frame (by trackball) 2 Touch LVAd ap 4 MOD Move cursor to position at endocardial border of basal septal segment on mitral valve plane. 3 Press Trace 4 5 Perform Tracking Press Enter twice 6 7 Print Out (for documentation of LV-Volumes) 8 Press Erase 18

  21. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue UNENHANCED a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAs ap 2 - MOD) 1 Touch Loop, touch Display, Go to page 2 from 8 (2/8) (a2CV) Select endsystolic frame (by trackball) 2 Touch LVAs ap 2 MOD 3 4 Move cursor to position at endocardial border of basal inferior segment on mitral valve plane. 5 Press Trace 6 Press Enter twice Perform Tracking 7 Print Out (for documentation of LV-Volumes) 8 9 Press Erase 19

  22. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF biplane(LVAd ap 2 - MOD) Select enddiasstolic frame (by trackball) 1 2 Touch LVAd ap 2 MOD Move cursor to position at endocardial border of basal inferor segment on mitral valve plane. 3 Press Trace 4 5 Perform Tracking Deactivate Results Box 6 Press Enter twice 7 Print Out (for documentation of LV-Volumes) 8 Touch Report + Print Out report 9 Insert derived volumes (--> see print outs) / EF (--> see report) from biplane and monoplane a4CV measurements into CRF-Page 18 10 20

  23. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF monoplane a3CV(LVAs ap 4 - MOD) Touch Erase All and confirm with Enter 1 Touch Loop, touch Display, Go to page 3 from 8 (3/8) (a3CV) 2 3 Select endsystolic frame (by trackball) 4 Touch Analysis and EF & Volumes 5 Touch EF (MOD-bp) and LVAs ap 4 MOD Move cursor to position at endocardial border of basal posterior segment on mitral valve plane. 6 10 Print Out (for documentation of LV-Volumes) 7 Press Trace and PerformTracking Press Erase 11 Press Enter twice 8 21

  24. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality SonoVue a 4CV s a4CV d a2CV s a2CV d a3CV s a3CV d LV-Volumes and EF monoplane a3CV(LVAd ap 4 - MOD) Select enddiasstolic frame (by trackball) 1 Touch LVAd ap 4 MOD 2 3 Move cursor to position at endocardial border of basal inferior segment on mitral valve plane. Press Trace 4 Perform Tracking 5 6 Deactivate Results Box 7 Press Enter twice 8 Print Out (for documentation of LV-Volumes) Touch Report + Print out Report 9 Insert derived volumes (--> see print outs) / EF (--> see report) from monoplane a3CV measurements into CRF-Page 18 10 22

  25. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality Artifacts SonoVue Wall Motion Analysis Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 Perform segmental WMA (16 segment model). CK loops 5-8) may be used as additive information 2 23

  26. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality Artifacts SonoVue Endocardial Border Delineation Image Quality Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 Perform segmental EBD (16 segment model). 2 Assess overall image quality according to the score given on page 15 of the CRF 2 24

  27. Loop Selection from MOD EF biplane EF a 3CV WMA EBD Image Quality Artifacts SonoVue Contrast Quality - Artifacts Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob. 1 Assess contrast artifacts according to the score on page 18 of the CRF 2 25

More Related