Implant Surface Adhesion Analyzer. Group Members: Brad Galpern Katie Knudson Kory Nelson Academic Advisor: Sean Kohles, PhD Industry Sponsor: 3I. Gap. Surface roughness of implanted materials affect adhesion quality Macro scale testing borrowed from other industries.

Related searches for Implant Surface Adhesion Analyzer

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Implant Surface Adhesion Analyzer' - amy


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Implant surface adhesion analyzer l.jpg

Implant Surface Adhesion Analyzer

Group Members: Brad Galpern

Katie Knudson

Kory Nelson

Academic Advisor: Sean Kohles, PhD

Industry Sponsor: 3I


Slide2 l.jpg
Gap

  • Surface roughness of implanted materials affect adhesion quality

  • Macro scale testing borrowed from other industries

http://www.instron.us


Objective l.jpg
Objective

  • Design an apparatus to investigate the effects of various surface topographies on the adhesion of implants to bio-materials.

    • Simulate mode 1 fracture

    • Apply, measure and correlate force and displacement data

    • Scaleable

IMMEDIATE OCCLUSAL LOADING™ (IOL™) OF DENTAL IMPLANTS: Predictable Results Through DIEM™ GuidelinesRichard J. Lazzara, DMD, MScD


Objective4 l.jpg
Objective

  • Force vs Roughness crack length

  • Force vs Linear crack length

Images courtesy of Dr. Kohles


Design components l.jpg

Frame

6061 Al

Pyramid design - strength, visual access

Secure specimen jig

Houses motor and laser

Electric Motor

3V

1300 to 1 Gear reduction

Design Components


Design components6 l.jpg
Design Components

  • Specimen Jig

    • 6061 Al

    • Simulate mode 1 fracture

    • House test specimens

    • Houses other components

  • Sensor Array

    • Input light and voltage, output resistance

    • Scaleable


Design components7 l.jpg
Design Components

  • Laser

    • Powerful and concentrated light

    • Fanned horizontally

    • Drastic contrast to ambient light

  • Force Sensor

    • Compression sensor adapted

    • Input voltage and force, output resistance


Design components8 l.jpg
Design Components

  • Test Specimens

    • Machined plastic bars

    • Simulated bio materials

    • Varying mechanical properties





Conclusion l.jpg
Conclusion

  • All design components are scaleable

  • Proof of concept achieved