An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements Xavier Llopart, CERN Vienna, Feruary 2007

  2. Outline • Medipix2 • From Medipix2 to Timepix • Timepix chip • Electrical characterization • First Images • Summary

  3. Medipix2 • Square pixel size of 55 µm • Sensitive to positive or negative input charge • Pixel by pixel detector leakage current compensation • Window in energy as precise as possible • 14-bit counter per pixel with overflow control • Count rates of 1 MHz/pixel (0.33 GHz/mm2) • 256 x 256 pixels • 3-side buttable • serial or parallel I/O

  4. 14080 m (pixel array) 16120 m 14111 m Medipix2 (II) • 6 metal layers IBM 0.25um • Serial readout <5ms@180MHz • Parallel readout <300us@120MHz (>1KHz frame !!!) • Static power consumption ~550mW • >35 Mtrts • Sensitive area ~2cm2 • Available in 2002

  5. Medipix2 collaboration • Form by 17 institutes (16 EU and 1 US) • Applications: • Dental radiography • Mammography • Angiography • Dynamic autoradiography • Tomosynthesis • Synchrotron applications • Electron-microscopy • Gamma camera • X-ray diffraction • Neutron detection • Dynamic defectoscopy • Adaptative optics • Radiation monitor • > 100 publications in the last 5 years (http://www.cern.ch/Medipix) • Medipix3 collaboration started last September (“The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode with Improved Spectrometric Performance”, R.Ballabriga, IEEE NSS-MIC 2006)

  6. 50um GEM Micromegas From Medipix to Timepix • A novel approach for the readout of a TPC at the future linear collider is to use a CMOS pixel detector combined with some kind of gas gain grid • Using a naked photon counting chip Medipix2 coupled to GEMs or Micromegas demonstrated the feasibility of such approach

  7. Motivation: Medipix → Timepix • These experiments (by NIKHEF, Saclay and Freiburg 2004/2005 ) demonstrated that single electrons could be detected using a naked Medipix2 chip 2D • Did not provide information on the arrival time of the electron in the sensitive gas volume  3D (position + time) • The Timepix chip has been designed as an evolution of the Mpix2MXR20 with a time stamp with a tunable resolution of 100 to 10ns. • Requirements: • Keep Timepix as similar as possible to Medipix2 in order to benefit from large prior effort in R/O hardware and software. • Avoid major changes in pixel and/or readout logic – risk of chip failure due to poor mixed mode modeling. • Keep 2nd threshold if possible → TOT measurement • This modification has been supported by the JRA2/EUDET Collaboration (www.eudet.org).

  8. Timepix Pixel Schematic Previous Pixel Ref_Clkb Clk_Read Mux 4 bits thr Adj Mask Mux Preamp Input Disc 14 bits Shift Register Shutter Timepix Synchronization Logic THR Shutter_int Ctest P0 Conf Testbit Polarity P1 8-bit PCR Test Input Ovf Control Ref_Clk Clk_Read Next Pixel Analog Digital

  9. Ref_Clk distribution • Power uniformly distributed over clock period → minimize coupling • ~50ns to distribute the clock all over the chip • ~500mW @100MHz (simulations) Ivdd[mA]  2·f[MHz] ~50ns ~0.820mA/col  ~210mA/chip

  10. Medipix Mode TOT Mode Timepix Mode Timepix Synchronization Logic (TSL) • Each pixel can be configured independently in 3 different operation modes • TSL synchronizes the Ref_Clk with hit an Shutter • Minimized power consumption in stand-by (no hit) • Each pixel can be masked independently • Maximum number of counts→11810 (~230µs @Ref_Clk=50MHz)

  11. Timepix Pixel Layout Timepix layout • Preamplifier: • 90-180ns peaking time (Preamp DAC) • 0.5µs-2.5µs constant current fall time Qin<10ke- (Ikrum DAC) • Sensitive to e- and h+ with leakage current compensation • Nominal gain ~16.5mV/ke- • Output voltage dynamic range ~50ke- • Discriminator: • Polarity control • 4-bit threshold adjustment DAC • Hysteresis • Pixel analog power → ~6.5µW (20x55 µm2) • ~50 transistors • Pixel Configuration Register • 4 bit threshold adjustment • 2 bit pixel operation mode (P0 and P1) • 1 bit mask • 1 bit test pulse • Timepix Synchronization Logic: • Counter clock synchronization (Mode operation) • Ref_Clk pixel buffer • 14-bit shift register: • LFSR with 1 XOR tap → 11810 maximum counts • Overflow control • Pixel digital ‘static’ power → ~6.5µW@100MHz (35x55 µm2) • ~500 transistors

  12. Medipix → Timepix Layout Mpix2MXR20 layout Timepix layout

  13. Timepix chip architecture • IBM 0.25µm CMOS • Chip architecture almost identical to Mpix2MXR20 • M0=M1=1 and Shutter ON -> FClock used as Ref_Clk • 256x256 55µm square pixels • Analog Power -> 440mW • Digital Power (Ref_Clk=80MHz) -> 450mW • Serial readout (@100MHz) -> 9.17 ms • Parallel readout (@100MHz) -> 287 µs • > 36M transistors • Chip available November 2006

  14. ‘Official’ Medipix readout systems • MUROSv2.1: • Serial readout • VHDCI cable length <3m • ~40fps @160MHz • Tunable readout clock [30-200MHz] • Already compatible with Timepix • http://www.nikhef.nl/pub/experiments/medipix/muros.html • USB1.1: • Serial readout • ~5 fps@20MHz • Not compatible with Timepix • HV generator • http://www.utef.cvut.cz/medipix/usb/usb.html MUROSv2.1 USB

  15. Pixelman Software • Compatible with Medipix2.1, Mpix2MXR20 and Timepix. • Compatible with USB and Murosv2.1 serial readout systems • Compatible with single chip or multi-chip (quad) PCBs • High flexibility: Several USBs and Murosv2.1 systems controlled simultaneously • http://www.utef.cvut.cz/medipix/Pixelman/pixelman.html

  16. Timepix wafer map • Yield (on 7 wafers): • Test includes for each chip: • Digital Test • Chip ID • Write/Read matrix test • Analog Test: • DACs scan • Tespulse Test (Medipix and TOT)

  17. Timepix electrical characterization • ‘Naked’ mounted in standard PCB • Murosv2.1 and Pixelman software • The calibration test pulse : • Dynamic range of ~40ke- • Gain ~46e-/mV (based on simulations) Standard PCB

  18. Shutter PreampOut Thr discOut CounterClk Pixel measurements • From the 2 test pixels [120:121,0] one can measure the preampOut, discOut, internal Ref_Clk and the counter clock • State Machine of the counter Modes (P0, P1) work as expected • No visible coupling of the Ref_Clk signal into the analog signals (preampOut and discOut)

  19. TOT Mode Time Mode Reconstructed analog output Shutter THL PreampOut • Combining threshold scan with arrival time and TOT mode → reconstruct all pixels analog output • Amplitude and timing information is revealed for all pixels • Fantastic tool !!!

  20. ‘Reconstructed’ analog output : DACs optimization • Measurement in pixel [128-128] • ∆Ikrum, ∆Preamp and ∆Qin

  21. Different polarity (h+ and e-)

  22. Counts 97.75% 50% 2.25% THL (ke-) Counting Mode • Hole collection: • Gain ~16.5 mV/ke- • ENC~99.4 e-rms • THL DAC step ~24.7 e- • Electron collection: • Gain ~16.5 mV/ke- • ENC~104.8 e-rms • THL DAC step ~25.4 e- • Excellent linearity in both collection modes

  23. Measured TOT [µs] TOT mode • Very good linearity if Qin>Qthr+3ke- • TOT linearity up to 200ke- (simulations) • ∆TOT/TOT is <5% if Qin>Qthr+1ke- ∆TOT/TOT [%]

  24. Time arrival mode • Time-walk: Qin=Qthr + 1ke- → ∞ • Measured Time-walk <50ns

  25. Timepix matrix equalization • Equalization using the noise as trigger and Medipix Mode (P0=P1=0) • The measured INL of the 4-bit DAC is < 0.8 LSB → Interpolation in the equalization can be used → <2min for chip equalization • Minimum detectable charge: 6 √(σENC2+ σthr2) → ~650e- σ= ~31 e- σ= ~33 e- σ0=245 e- σ15=245 e- σ15=234 e- σ0=237 e- THL (e-) THL (h+)

  26. Arrival time mode • Injection of ~2ke- input pulse at Thr~=1ke- → 99% pixels with 1003-1004 !!! • Injection of ~20ke- → 99% pixels with 1005-1006 !!! • Matrix time-walk [(Thr+1Ke-) → ∞] is <50ns at nominal settings (Ref_Clk=50MHz) • Could be improved with TOT measurement

  27. Pixel to pixel TOT gain variation Pixel to pixel TOT gain variation • The return to zero variation from pixel to pixel generates in TOT mode a pixel to pixel variation for the same global threshold • In counting mode and time arrival time this effect is not present

  28. Fixed pattern correction mask in TOT mode • A correction mask for this effect can be found by calculating the transfer function of each pixel by scanning the test pulse over a fix global threshold. Counts Energy (ke-)

  29. 10 test pulses in mixed mode

  30. Timepix with 3-GEM detector • DESY testbeam in November 2006 (A.Bamberger, M.Titov)

  31. Timepix with Micromegas • Nikhef January 2007 (thanks to J.Timmermans)

  32. Medipix2 vs Timepix

  33. Timepix chip is a modification of the Medipix2 chip to gives arrival time information. A distributed clock is used as time reference. 3 selectable operation modes per pixel. Chip works as expected and already first results (GEMs and Micromegas) show very ‘exciting’ results First Si assemblies available in less than 1 month → Absolute calibration using X-ray sources. Conclusions and Future plans

  34. Online Timepix operation demo available…