1 / 24

g-2 phase study from GEANT simulation

g-2 phase study from GEANT simulation. Qinzeng Peng Advisor: James Miller Boston University Sep 28, 2004 Muon g-2 collaboration at BU: Lee Roberts, Rober Carey, Jon Paley, Xiaobo Huang Institutes: BU, BNL, UIUC, Univ. of Minnesota, Yale Univ. Outline. Brief introduction to g-2

aminia
Download Presentation

g-2 phase study from GEANT simulation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. g-2 phase study from GEANT simulation Qinzeng Peng Advisor: James Miller Boston University Sep 28, 2004 Muon g-2 collaboration at BU: Lee Roberts, Rober Carey, Jon Paley, Xiaobo Huang Institutes: BU, BNL, UIUC, Univ. of Minnesota, Yale Univ.

  2. Outline • Brief introduction to g-2 • Experimental set up and simulation • Simulation results and analysis

  3. What is g-2? magnetic moment gyromagnetic ratio spin • Dirac equation predicts g=2 • in nature radiative correction makes g≠2 where aμ(SM) = aμ(QED) + aμ(hadronic) + aμ(weak) aμ(New Physics)= aμ(Measured) −aμ(SM) Studied Muon instead of Electron due to

  4. Experimental Setup – Muon storage Polarization Momentum Idealorbit Kicker Modules R=711.2cm d=9cm Electric Quadrupoles Protons Pions Inflector (from AGS) p=3.1GeV/c Target (1.45T) Injection orbit • Muon polarization • Muon storage ring • injection & kicking • focus by Quadrupoles Storage ring

  5. DET magic γ= 29.3 spin precession and muon decay • muons move in circle with constant speed • spin precession (Thomas + Larmor) • electrons decay mostly along the spin • direction and boosted by Pmuon • fitting by 5-parameter function to get N(t,E) = N0(E)e-t/τ(1+A(E)Cos(ωat+Φ(E))

  6. Phase shift on ωa uncertainty What if φ is not a constant? Take an example: if And measuring time is about 600 μs, then

  7. Idealorbit g2Geant simulation Hugh Brown • Muons generation • Spin polarization Beam-line simulation Jon Paley Inflector p≈3.1GeV/c g2Track • Inflection • Kicking • scraping Robert Carey g2GEANT Simulates nearly all geometric set up in the storage ring DET

  8. Vert. on DET Vert. in Beam Radial in Beam Radial on DET tdecay-tmeasure=drift time Beam-line / Calorimeter alignment vertical Beam in the ring Calorimeter horizontal

  9. Data selection • Energy cut: En >1.8GeV • Detector dependence: average over 24 detectors • Drift time: offset of g-2 phase

  10. Ф vs. detector vertical position DET Beam 3cm ypc1 • Symmetric about center • Energy dependent • ΔΦbig : -80 ~ +80 mrad • Φ(all) small : about 5 mrad • Φ change sign at 3cm

  11. inward outward 3cm outward and inward decay

  12. Ф vs. detector radial position • ΔΦ smaller, 30 mrad • Φ≈0 on outside • Φ >0 on detector

  13. Ф vs. beam vertical/radial position • ΔΦ smaller • Φ≈0 on inside • Φ >0 • symmetric about center of beam • ΔΦ big • Φ≈0 at center

  14. Beam vertical shift • ΔΦ ≈0 • Φ is detector dependent, 4 groups --- 4 Quads

  15. Beam width change idea: change beam vertical distribution by a weighting factor Result : 1 percent width change / 0.1 mrad phase shift

  16. Beam upper cut – muon losses 9cm • Muon losses: 1.64% • ΔΦ = -0.323 mrad

  17. DET Vert. Detector gain shift 1.05 E 0.95 E E • very small effect • 10% gain shift / • ΔΦ = 0.014 mrad

  18. Beam / detector vertical alignment • 0.11%/1.0% width change • 0.9mm/1.0mm shift

  19. CBO modulation • Betatron Oscillation • Coherent Betatron Oscillation • Combine 23 detectors in one CBO period Time = MOD ( time - DET# /24*Tcbo, Tcbo)

  20. Sampling  Tcbo=2.4μs

  21. CBO effect Combine 23 detectors

  22. CBO modulation Number modulation Asymetry modulation, 0.22%

  23. phase modulation, 0.358 mrad dt modulation, 0.175 mrad

  24. conclusions • Simulation results consistent with Real data, like FSD studies. • Phase shift due to the geometric set up is a small effect on ωa . • CBO effect is a small effect.

More Related