1 / 49

A Little Background

Life After I-DEAS - Part II TCII, NX/Teamcenter Integration, and CMM – A User Perspective Matt Peyton Moog Components Group Sr. Designer/CAD Administrator mpeyton@moog.com Brian Garcia Metafore Sr. PLM Applications Engineer brian.garcia@meta-fore.com. 1. A Little Background.

Download Presentation

A Little Background

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Life After I-DEAS - Part IITCII, NX/Teamcenter Integration, and CMM – A User PerspectiveMatt PeytonMoog Components GroupSr. Designer/CAD Administratormpeyton@moog.comBrian GarciaMetaforeSr. PLM Applications Engineerbrian.garcia@meta-fore.com 1

  2. A Little Background • Moog Components Group (MCG) has been using I-Deas since 1997 • I-Deas has served us well in those 10 years • We saw migration to NX as inevitable • I-Deas updates becoming sparse • NX had more features we wanted • Acquisitions forced this process to be sped up • Met Meta-Fore at PLM World ’07 and contracted them to do our Teamcenter setup, migration & training

  3. After TDM Migration…. After migrating all TDM data into Teamcenter (see Part I of this presentation), what’s next? If you are like us, you will want to begin using NX as soon as possible Take advantage of Dual Licensing I-Deas and NX can be run side-by-side if versions are aligned (i.e. NXI5 & NX5) Allow users to tinker with NX locally (outside of Teamcenter) Get accustomed to Teamcenter Get Training!! 3

  4. TCII - Using Teamcenter with Ideas Meta-fore set up “TDM” searches and a migrated folder structure that mimicked TDM Project/Library hierarchy Once data starts being manipulated and created, these searches and folders quickly become obsolete Most users will get used to the Teamcenter searches as a more efficient way to find data Encourage use of folders for personal organization Can be used in a similar way that model files were used 4

  5. TCII – Cont’d Make sure users understand what they are seeing in Teamcenter Understand the differences between Item, Item Revisions, and Datasets 5

  6. The Box Analogy Item Item ID

  7. The Box Analogy Item rev Item Rev Master Item rev Item master Item rev dataset Item dataset

  8. TCII – Cont’d • Encourage use of Model File View as opposed to Manage Bins • Model File View is more robust and promotes the “Teamcenter” style interface • Help users understand Teamcenter equivalents

  9. TCII – Cont’d • Use the Model File View “display filters” • Will make looking at the data easier to understand • Make sure users understand how to update their parts from Teamcenter in the Model File View window • Turn on your “Check-Out By” Column in Teamcenter • Make sure users know to use Send-To Ideas, and not right-click > Check Out • This will most likely happen a lot during the first couple weeks of TCII use

  10. TCII - Limitations • Understand that I-Deas was not created to work with Teamcenter • Some basic TDM functions have no Teamcenter Equivalent • Update in Library • Ham_Medic.exe • This has caused us some grief • TCII 5.1 has option to run Ham_Medic.exe on checkout • We have not tested this at our site yet

  11. TCII – Limitations – Cont’d • Renaming items can be difficult in Teamcenter • Naming it right the first time is the best option • TCII Errors are typically vague • “Fix in I-Deas First” usually means your part or drawing needs to be updated prior to check-in • Occasionally model file will become “out of sync” with Teamcenter • “Synchronize Model File” usually fixes this problem

  12. Setting up NX • Site wide defaults and templates can be read from a network location with the proper permissions and shares • We just copied the entire UGII folder to the network and tweaked everything from there • ugii_env.dat is the master file for NX Settings • UGII_ENV_FILE should be set in the environment variables for all users to point to the network location of the new ugii_env.dat file • Alternatively, this variable can be set in the start_ugmanager.bat file found in the Teamcenter Portal folder • This will only set the defaults when NX is ran from Teamcenter, not local

  13. Modifying ugii_env.dat • Very similar to modifying ideas_paramXX.dat • If you can do that, you can do this • First and foremost, add the following variable: • UGII_BASE_DIR=“network location of the UGII folder” • This will save you time, as it will determine where the file looks when it sees ${UGII_BASE_DIR} • Now all settings and parameters should be reading from the network location you created • Network permissions should be controlled similar to network permissions of the “SDRC\Team” directory

  14. Setting User Profiles and Defaults • We set our user profiles and user defaults to be located on each users personal network drive • This ensures their settings follow them from computer to computer • Less setup when a user gets a new computer • In the ugii_env.dat set the following • UGII_USER_PROFILE_DIR=[Network Location]\nxdata\user_settings • UGII_LOCAL_USER_DEFAULTS=[Network Location]\nxdata\user_settings\nx5_user.dpv

  15. Customer Defaults Customization • If you are customizing the customer defaults, you will need to create another folder in the same directory as UGII on the network • We called ours “customer_defaults” • In this folder, create a folder called “startup” • Copy nx5_user.dpv (located under the users Local Settings\Application Data\Unigraphics Solutions\NX5) to this folder and rename it nx5_site.dpv • The permissions for this “customer_defaults” folder should be set to control who can access and change site wide settings • In the ugii_env.dat file, add the following setting • UGII_SITE_DIR=${UGII_BASE_DIR}\customer_defaults

  16. Customer Defaults Customization – Cont’d • In NX5, go to File > Utilities > Customer Defaults • You should now have a Defaults Level pull down for Site, & User • User settings will override any site setting that is not locked • Default Levels are read in the following order • Site • Group * • User • The lower level settings override the previous level’s *To set the group defaults, use a similar tactic as setting the site defaults

  17. Drafting Standard Customization • While in NX5, set the Defaults Level to Site and navigate to Drafting • Click Customize Standard, and do a Save As to create a new standard • This file should save into the customer_defaults location you created • You now have Custom Site settings, and a Custom Drafting Standard that can be tweaked to your site’s needs

  18. Customer Defaults – Misc • Lock any setting at the site level that you do not want tweaked at the group or user level • We have the following settings locked • Drafting Standard • Default Units • Locking Policy • We were told by GTAC to set this to Automatic or problems would arise • Use the “Binoculars” to find specific settings • This is a real time saver • Use network permissions to control who has access to change settings at each level

  19. Setting up Seed Parts • Seed parts are controlled by PAX files • These files are located under {UGII_BASE_DIR}/UGII/templates • nxdm_ugs_drawing_templates.pax • nxdm_ugs_model_templates.pax • nxdm_ugs_sheet_templates.pax • nxdm_ugs_cae_templates.pax • Edit the PAX files to only show the seed parts you wish to see (or to add in your custom seed parts) • This controls what the user will see during a “File > New” • Template files are located in Teamcenter, and can be modified or completely new seed parts can be created • Do a Teamcenter search for *template*

  20. Setting up Seed Parts – Cont’d • Know that some settings must be controlled in the seed part as opposed to the Customer Defaults • Most things that are under Preferences • Custom Attributes • Layer definitions • Load and Save options • Must have DBA access to edit Seed Parts • nxdm_ugs_sheet_templates.pax controls what files will be used during Insert Sheet > Use Template • This can also be added to the resource bar as a Palette if needed

  21. Setting up Drawing Templates • Edit the Drawing Templates and Sheet Templates PAX files to control your Drawing and Sheet Templates • Drawing templates can be imported in from I-Deas via CGM • Text will be converted to line • A way around this is to import as DXF, then CGM out and back into NX • Use Attributes to fill in your title block text • <W@DB_PART_NAME> = Part Name • <W@DB_PART_DESC> = Part Description • We use this for our Part Number at MCG • <W@DB_PART_REV> = Part Revision • <W@$SH_SHEET_SIZE> = Sheet Size • For a full attribute list look in the NX5 Help files

  22. A Quick Note about Drawing Scale Attribute • SCALE <W@$SH_SHEET_SCALE_NUMERATOR>:<W@$SH_SHEET_SCALE_DENOMINATOR> • When inserting a view, you have a scale option similar to I-Deas • This attribute is not the same as the drawing scale attribute • After placing views (or prior to placing views) double-click (or right-click) the drawing border and set the scale there • This will update all views to the scale you specify, and maps to the Drawing Scale attribute in your title block

  23. Setting up Custom Roles • Very easy to do • We tweaked the existing roles (Advanced with Full Menus) • Create a folder in the existing “startup” folder on your shared network location called “roles” • Modify Toolbars, Resource Bar, etc… to how you want them in your role • Right-Click any toolbar > Customize >Roles tab • Click Create and save to the shared “roles” folder *Note: if you want custom images to show up, they must be located in a shared location where the users have write privileges*

  24. Some Thoughts on NX Training Most users will pick up basic modeling and assembly very quickly Make sure to spend time on drafting Drastically different Detailing of models in NX5 is a big improvement over I-Deas Basic 2D and adding 2D data to drawings is perplexing and cumbersome to use compared to I-Deas Something you have to learn to get used to Coming from I-Deas, we found this aspect of NX5 the least appealing 24

  25. Training – Cont’d Spend some time on Data Management with Teamcenter Very different from TDM and TCII Once part is opened and modified, a “soft” check-out lock is created There is no Reference/Read Only for users of the same group Lock is removed when part is closed When 2 or more users of the same group are working on the same project, problems arise “Hard” check-outs resolve this issue….sometimes We are still struggling with this at MCG Problems could possibly be circumvented using Teamcenter Groups and Teamcenter workflows effectively 25

  26. Training – Cont’d • Spend some time on the Assembly Navigator • There are a lot of powerful tools in there • Reference Sets • Dependencies Browser • This is how you view assembly constraint relations • Closing and Opening Parts • Working In Context of Assembly/Drawing • Learn basic WAVE functions • Can be used in a similar way to Associative Copy in I-Deas • Very powerful tool with endless uses • Use the Command Finder • Utilize CAST (Computer Assisted Self Teach)

  27. Lost FunctionalityBetween NX5 & I-Deas • Modeling • Irregular patterns/arrays – NX5 does not support this • Instance clocking can be used • Causes CMM’d parts to create BREP’s • Defining X & Y vectors of a rectangular pattern – can not be done on the fly in NX5 • Must re-orient the WCS • Mirroring a body without keeping the original – can not be done in NX5 • Similar effect can be achieved using reference sets or layers

  28. Lost Functionality – Cont’dBetween NX5 & I-Deas • 2D Drafting – Basic 2D functions • Very difficult to use compared to I-Deas • Use “Expand Member View” to insert Curves (Lines) into drawings • This isolates “Curves” to a single view • Editing a “Curve” after inserting it proves difficult • Use the Sketcher in 2D • Create User Defined Symbols • Use tables/Tabular Notes – these are great • Can be driven by a spreadsheet

  29. Lost Functionality – Cont’dBetween NX5 & I-Deas • Step File Translations • Assembly Step Files can not be imported directly into NX with Teamcenter • They must either be done in a local NX session, or as “New Parts” (creates local files) • Then imported into Teamcenter using Tools > Teamcenter Integration > Import Assembly • This has some nice features such as “Number Generator” • Transferring 2D information (non-text) from drawing to drawing must be done using CGM export/import • This is very similar to Ideas 2D Symbols/Instances

  30. Gained Functionality(hey, it’s not all bad) • Detailing of Models is much faster and easier • Broken Views • Detail Views • Revolved Sections • Much easier to maintain dimensional associations to model • Layers (that are easy to use) • The NX5 Hole command • Very robust (once you get used to it) • Centerlines that work much better than I-Deas

  31. Gained Functionality – Cont’d • Spreadsheet driven Tabular Notes • Part Families • Attributes • Can be used to streamline your templates and seed parts • Sheet Metal • Much better than I-Deas • Very user friendly and easy to learn and use • Sketcher • Similar to I-Deas, but better • Trim works! • Mirror sketch – Retains constraints

  32. Gained Functionality – Cont’d • WAVE Linker • Can achieve some very tricky geometry • Ties geometry and features between parts • Will require an additional license to unlock it’s full potential • Direct Modeling • Datums • Very usable and easy to modify • New Assembly Constraints • Specifically “Center” & “Concentric” • Expression Editor

  33. More Gained Functionality… • Re-orient sketch • Can get you out of situations that would have been pretty hairy in I-Deas • Very useful on CMM migrated parts • Sketch Drag • Just click on the sketch and drag it, evaluates constraints in real time • Convert to/from Reference • Very easy to do • Saves time and preserves design intent • Multiple Sketches that can be tied to each other • Can be cross planar

  34. Even More Gained Functionality…. • Extrude/Revolve with offset • Very cool feature • Saves time • UNDO! • CSYS (Coordinate System) – Very usable • Much easier to manipulate than I-Deas CSYS • “BORN Blue” now “BORN Red” • Just move the sketch curves around to evaluate sketches similar to “Show Free” • “Bushy Tree” now “West Virginia Family Tree” • No branches

  35. CMM • Works VERY well for Assemblies and Models • Most assembly constraints make it through • Most model features make it through • Typical features that cause BREPs • Fillets (#1 offender) • Irregular Patterns • “Fancy” extrudes or revolves • Yellow Nodes (depending on your settings) • Yellow nodes can either be fixed in I-Deas first, or created as BREPS • We were originally fixing these in I-Deas but quickly switched them to BREPs

  36. CMM – Cont’d • BREPs can be handled very easily in NX5 using Direct Modeling • NX6 possibilities are even better • Manipulating I-Deas CAD data in NX surprisingly easy • Use “Reattach Sketch” to re-orient former cutter parts • Use Edit Sketch instead of Edit Sketch with Rollback • Boolean sections not shown in NX • Edit Sketch retains outline of model with sketch overlay • Red Nodes must be fixed in I-Deas prior to migration • Parts must be up-to-date in I-Deas prior to Migration • Can not be checked out • CAN be referenced in a model file (though not Ideal)

  37. CMM – Identifying Revs for Migration • This can prove difficult • Our approach was to use “Assembly View” under the top level Item Rev and copy those items into a specific folder • This must be done for all sub-assemblies as well • Can be time consuming • Usually will always miss something • Drawings that have a separate ID will need to be found as well • Search, search, search

  38. CMM – Issues we have run into • Mostly concerning drawings • Drawings do retain associativity to model, and are typically accurate • Use the drawing compare overlay tool • Does not work for multiple sheets • Can be worked around by exiting without saving and re-opening • Views are created “from part” in NX • Can make things difficult when trying to update the drawing to the model • This caused us problems with geometry not showing

  39. CMM – Issues – Cont’d • Other issues with migrated drawings • Projection angle of drawing will be changed to it’s opposite (First Angle will be Third Angle, vise-versa) • Does not affect existing views, only views added/projected after migration • Recommended to fix this prior to drawing approval, or at least make your users aware • Detail views come across as two views • One view of the geometry • One view of the dimensions • We have found it easier, (and cleaner) to simply re-create the drawings if there are drastic changes • A better drawing will be retained as a result • We have not been doing this for basic “Change Order” type changes

  40. CMM – Issues – Cont’d • Drawings from assemblies seem to have the most issues • Reference Sets may need tweaking • Disappearing and/or invisible Geometry • Sometimes can be fixed with View Dependent Edit > Delete All Edits • Sometimes part must be “un-blanked” • 1.) Component is grayed out which means it is blanked • 2.) Select on Component -> MB3 -> Replace Reference set -> MODEL • 3.) Select on Component -> MB3 -> Show Only which will blank everything • 4.) select on Component -> MB3 -> Show which will bring back all of the parts and then update all of the views.

  41. CMM – Unique Solutions to Consider • We had a simple hardware part that would not migrate into NX • NX Dataset was created, but blank • Rather than spend time trying to evaluate the problem, we took the MacGuyver approach • Created a STEP file out of I-Deas and imported it into the blank NX Dataset • Hardware was still associated with model • Nice! • So far, we have had one other file that would not migrate fully into NX • A Drawing that stops at 70% • This is an open GTAC IR

  42. CMM – Suggestions • Go to the Migration Lab • Learn how to use CMM tools • Become comfortable • Get on the CMM distribution list • CMM is constantly being updated and enhanced as users like us place calls to GTAC • Don’t be afraid to call GTAC • You will get to know Sonia Kelley & Ron Davis very well • Practice makes perfect • Practice in a test environment as much as you can • Limit the number of CMM operators

  43. Things you should know(that we didn’t’) • You will most likely need some additional licenses • You should receive a 1 to 1 I-Deas to NX license exchange, however some functionality will be lost • Advanced Assembly (in order to do weight/mass analysis) • NX Data Management is VERY different from I-Deas/TCII • Problems arise when multiple users work on same parts • 2D drafting is VERY difficult and time consuming compared to I-Deas • This is NX5’s weakest aspect • CMM is not being used by a large customer base • Lot’s of progress has been made with CMM, but you will still be near the forefront on this

  44. Other Suggestions • Get a Space Ball • NX was designed to work with a Space Ball • Using the mouse for movement can be difficult • Accidentally closing/completing commands • If you don’t have a Space Ball, Shift & Control keys can be used similar to F-keys in I-Deas • Do not use the “I-Deas” role • It is a crutch • Learn NX as NX, not I-Deas • Does not give you full functionality • Sys Admins – Get Teamcenter Admin training • TC Admin training will touch on NX Admin • To my knowledge, there is no NX Admin class

  45. Other Suggestions – Cont’d • Utilize all available resources • Help files • CAST • GTAC • Online forums • User Groups • Company resources if available • Get help for your migration and setup, either from UGS or some other source • There is no way we could have completed our migration as fast and successfully without Meta-Fore

  46. Closing Thoughts • NX5 is very good CAD software and a welcome step forward from I-Deas • A few things still need to be tweaked to ensure a more seamless upgrade for I-Deas users • “Legacy” Unigraphics commands can be difficult to use as an I-Deas user • Things can only get better from here as more I-Deas functionality becomes integrated with NX and New NX features are created and old ones updated • Overall the shift to NX5 has been fairly pleasant, with a few instances of wanting to pound our collective heads against a wall • After using NX5 you will not want to go back to I-Deas, even with NX5’s shortcomings

  47. Thanks to Meta-Fore Brian Garcia Laila Hirr Lee Guthrie Mike Nelson Randy Ellesworth Clarke Wingfield PLM World Bryan Cridlin Pat Turman A.D. Link Valerie Shrader Gary Morris Richard Kelley Andreas Lindenthal Irma Boehringer John Kirk Dennis McCoy Sonia Kelley Paul Bailey

  48. Apologies to Darwin

  49. Thank you Matt PeytonMoog Components GroupSr. Designer/CAD Administratormpeyton@moog.comBrian GarciaMetaforeSr. PLM Applications Engineerbrian.garcia@meta-fore.com