1 / 23

Summary of the presentation Outlook of convection monitoring at INM

Download Presentation

Summary of the presentation Outlook of convection monitoring at INM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RECENT PROGRESS IN CONVECTIVE PHENOMENA MONITORING AND FORECASTING AT THE INMF. Martín, F. Elizaga, I. San Ambrosio and J. M. Fernándezfrancisco.martin@inm.esServicio de Técnicas de Análisis y Predicción, STAP(Forecasting and Analysis Techniques Service)Instituto Nacional de Meteorología, INMwww.inm.es

  2. Summary of the presentation • Outlook of convection monitoring at INM • Integration of remote sensing data and NWP output: • Regional level: hail module • National level • Doppler radar-based products • Specific products for end-users • Conclusions

  3. Convection monitoring at INM: Basic approach • Specific oriented NWP output for deep moist convection: CAPE, CIN, SRH,… Maps from ECMWF and HIRLAM models • Pseudo sounding derived from NWP models and thunderstorm oriented parameters • MSG imagery and Nowcasting SAF products • Integration of remote sensing data: • Regional level • National level

  4. Specific oriented NWP output for deep moist convection: CAPE, CIN, SRH,.. maps from ECMWF and HIRLAM models: One example Lift Index & Wet bulb Potential Temperature at 850 hPa Low Level Winds & CAPE Storm Relative Helicity & Potential Instability at 700 hPa Convective Precipitation

  5. Integration of CG lightning and radar dataData and methodology • Data • Regional radar data: 1 PPI + 12 CAPPIs (0.5-16 km) + derived radar products (Echotop, VIL, ZMAX, ..) in non Doppler mode, every 10 min., 2 Km x2 Km. Other data in Doppler mode • National composite radar data: PPI, CAPPI-2.5 Km height, VIL, Echotop, ZMAX… en non Doppler mode, every 10 min., 2 Km x2 Km. Other data in Doppler mode • CG data, MSG-MET8 imagery and HIRLAM/ECMWF model output • Procedures for radar-based convective identification Two procedures have been adapted for monitoring and tracking of radar-based convective storms , taking to account the INM radar data and facilities: • Bidimensional procedure, 2D, is applied on lowest radar elevation on PPI/CAPPI/ZMAX images: Steiner-Youter-Houze, SYH, technique (regional and national data!!!) • Three dimensional procedure, 3D, is applied on the 12 CAPPIs: SCIT algorithm (“Storm Cell Identification and Tracking”), developed by Johnson et al. (1998). At regional level!!!.

  6. Integration of lightning and radar data:(I) • Radar and lighting data fusion • 2D. PPI (CAPPIo ) (t) + lightning data (t-10 min., t) are combined. Radar-based convective objects + CG strikes • Spatial integration at “t” and backward movement of 2D convective structure up to t-10 min., for a temporal integration • Linear extrapolation of lightning and 2D convective structures up to 60 min. ------------------------------------------------------------------ • Cluster analysis • Non radar-combined “CG” strikes are clusteredby just distance criterion • Tracking and linear extrapolation of lightning clusters are not applied in the operational procedure

  7. Integration of lightning and radar data Regional and National levels:Flow Chart(II) MSG imagery as a background image (2005) IR10.8 at night HRVIS daytime

  8. Integration of lightning and radar data: (III) • Identification of convective structures, 2D: • Radar data to use: • Regional level: The lowest PPI (or a low CAPPI) • National level: ZMAX composite image • SYH, procedure for convective – stratiform separation (2D) • SYH convective criteria: • Intensity criterion • Peakedness or gradient criterion • Surrounding area criterion

  9. Integration of lightning and radar data: regional level (IV)

  10. Cluster Procedure (I) • Data • CG strikes, which have not been combined with convective radar structures, are clustered • Procedure • A lightning cluster is a set of CG flashes if for any lightning “i” exists at least other “j” and the distance Dij ≤10 km • A cluster is analysed if its CG number is superior or equal to 10 strikes (number of positive and negative strikes, centroid location, maximum and minimum distances among strikes) • None extrapolation is performed

  11. Cluster Procedure (II)

  12. Examples at regional level (I) • Radar ambiguities for long distances and mountainous areas • Example using Version 1.0

  13. Examples at regional level (II) • CG clusters at mountainous areas (radar screening) • Anomalous CG+ /PSD (Positive Strike Dominated) supercell

  14. Integration of lightning and radar data: national level (I) • Identification of convective structures • Radar image to use: A national composite image of maximum of reflectivity from regional radar data, ZMAX, every 10 min., 2 x 2 km • When a national pixel is covered by different radars, the maximum value of ZMAX is selected • SYH procedure for convective – stratiform separation is applied • The same procedure of assignment of CG and convective radar-based structure data is applied at national level • Clustering procedure is applied when CG lightings have not been assigned.

  15. Integration of lightning and radar data: national level (II) • Example: Thunderstorms over the Iberian Peninsula and airports graphical warning Airports

  16. Identification of 3D convective cell • SCIT: “Storm Cell Identification and Tracking” procedure, developed by Johnson et al. (1998), has been adapted at INM using the 12 CAPPIs from regional radar data every 10 minutes. • 3D Cell properties, extrapolation and tracking are performed

  17. Monitoring of deep convection at regional level (I): hail module Hail 2D Analysis: PPI+IR MSG +Lightning + NWP data 3D Analysis: 12 CAPPI + NWP data + hail Module

  18. Monitoring of deep convection at regional level (II): Close up view • Alicante supercell • Hail output: “G” denotes severe hail potential

  19. Doppler radar-based products • VAD (Velocity Azimuth Display) • Identification of mesocyclone (Version 0.1 non operational)

  20. VAD products

  21. Identification of mecocyclone Doppler radial velocity image Special patterns • Data.Wind radial velocity data of one Doppler PPI (Winr) • Methodology. Identification of special patterns with two well-defined and opposite maxima HRVIS Severe convection

  22. Specific products for end-users • Up to forty special hot spots (airports, cities), where special attention is needed, may be selected at each regional and national levels (i.e. aeronautical authorities) • Radius of surveillance are defined at each hot spot. • When a CG lightning strikes are into these circular areas or are likely to move into them, warning messages are issued.

  23. Conclusions • Objective procedures have been developed at INM to integrate different types of data at national and regional levels for monitoring deep moist convection. • Graphical and text format products are generated automatically for helping forecasters • External end-users are requiring special tailored products associating remote sensing information such as CG products. • Doppler radar-based products will be developed in the next future for monitoring convective wind velocity patterns (mesocyclone, intense convergence and divergence). • In the next future, GIS information will be included in the automatic procedures to enhance all remote sensing information.

More Related