An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ePHENIX forward tracker resolution “study” in EicRoot framework Alexander Kiselev EIC TF meeting,BNL Sep,262013

  2. Contents • ePHENIX surprisingly good fwd tracker resolution “puzzle” • Comparison to the dedicated EIC detector • ePHENIX realistic resolution plots in EicRoot framework • Summary A.Kiselev

  3. ePHENIX fwd tracker resolution (LoI) -> expected sp/p as good as ~3% at h = 3.0! A.Kiselev

  4. EIC dedicated detector resolution p+ track momentum resolution vs. pseudo-rapidity -> basically the same ~2-3% at h = 3.0 A.Kiselev

  5. EIC dedicated detector support plot #1 p+ track momentum resolution at h = 3.0 vs. Silicon thickness ->material budget matters! A.Kiselev

  6. EIC dedicated detector support plot #2 p+ track momentum resolution at h = 3.0 vs. Silicon pixel size ->detector intrinsic resolution matters as well! A.Kiselev

  7. ePHENIX detector layout A.Kiselev

  8. Other design considerations well, size also matters … sp/p (material budget) ~ 1/L sp/p (intrinsic resolution) ~ 1/L2 (assuming equidistant detector spacing and homogeneous magnetic field) -> and ePHENIXfwd tracker base (L) is at present ~3 times longer … A.Kiselev

  9. ePHENIX mock-up in EicRoot • 5x XY GEM stations at predefined locations • 50 micron gaussian resolution and 0.86% rad.length per plane • Either constant 1.5T or real-life BABAR-for-ePHENIX field • RICH material: 1.0% rad.length entrance window & ~1m thick CF4 gas volume • p+ tracks • Track fitting using Kalman filter A.Kiselev

  10. ePHENIX resolution plot #1 1.5T constant field; h = 4.0; check contributions (one change at a time) -> so really expect ~10% resolution at 10 GeV/c A.Kiselev

  11. ePHENIX resolution plot #2 1.5T constant field; h = 3.0 vs 4.0 -> a factor of ~3 difference in B*dl integral matters, clear A.Kiselev

  12. ePHENIXmagnetic field map -> field rapidly falls down beyond ~1.5m from the IP A.Kiselev

  13. ePHENIX resolution plot #3 1.5T constant vs realistic field; h = 3.0 & 4.0 -> real field gives a factor of ~2 worse results A.Kiselev

  14. ePHENIX resolution plot #4 realistic field; h = 4.0;“sp/p ~ a*p + b” breakdown ->linear term ~0.7% / GeV/c (~matches LoI number) A.Kiselev

  15. Summary • ePHENIXLoI momentum resolution numbers for forward tracker look reasonable (but whether this resolution suffices or not for RICH-based PID at h=4.0is a different question) • One might want to optimize dedicated EIC detector tracker layout (work started) A.Kiselev