1 / 17

Calorimetry + muon/p-id summary

Calorimetry + muon/p-id summary. Dhiman Chakraborty Northern Illinois University. Calorimetry. Performance goals Electromagnetic Calorimetry (ECal) Hadronic Calorimetry (HCal) Digital Analog Particle-flow algorithms (formerly energy-flow) Simulations

ajaxe
Download Presentation

Calorimetry + muon/p-id summary

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calorimetry + muon/p-id summary Dhiman Chakraborty Northern Illinois University

  2. Calorimetry • Performance goals • Electromagnetic Calorimetry (ECal) • Hadronic Calorimetry (HCal) • Digital • Analog • Particle-flow algorithms (formerly energy-flow) • Simulations • Particle identification (Digi/Ana) • Test Beam Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  3. Performance goals • Jet energy measurement precise enough to separate Ws and Zs in hadronic decays on an event-by-event basis: ΔE = 0.3 sqrt(E [GeV]) • Use track momenta for charged clusters; cal only for for neutrals: particle-flow algorithms • Identify non-pointing neutral clusters • Excellent hermeticity Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  4. ECal • Si-W (Oregon+SLAC) • Si-W-Scint (Kansas) • Scint-W (Colorado) • Crystal (Iowa+Caltech) • Cerenkov-compensated (Iowa+Fairfield) All analog Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  5. 0.5 cm x 0.5 cm 0.3 mm Si 3.5 mm/layer 30 layers Rin = ~142 cm Zmax = 2.1m 20X0, 0.8λ0 Sampling ~2% 5T field Small Rm and fine segmentation aids PFAs Europe on board Design well under way Electronics rough draft complete Mechanical conceptual design started. Tests, more simulations in the offing Si-W ECal Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  6. More affordable than Si-W Somewhat coarser segmentation – limited by fiber routing Fine sampling and timing Efficiency and uniformity need to be established – gang 3-5 tiles Choice of photodet, fiber coupling … Europe, Asia on board on scint. option Detailed simulation studies in progress Si-W-Scint. & Scint.-W Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  7. Inexpensive Excellent E resol. (100% sampling) No longitudinal segmentation – limitation to PFA? Still in early stage Extensive simulations needed and planned Cerenkov-compensated precision calorimetry Uses Cerenkov light to measure e,γ; ionization for hadrons, e – combine the two Not much known Crystal Cerenkov Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  8. RPC – Digital (ANL, U. Chicago, Boston, FNAL) Scintillator – Digital (?) (NIU, UIC) GEM – Digital (U Texas - Arlington) Scintillator – Analog (Colorado) ~34 layers, ~3.5 cm thick w/ 2.5 cm thick stainless steel or similar absorber ~ 4λ0, ~6% sampling 1-10 cm2 cells HCal Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  9. RPC DHCal • Multiple gas gaps, glass substrate, graphite/ink resistive layer • Avalanche mode operation • Prototypes constructed, electronics, DAQ in place, initial studies are very encouraging • Extensive testing, readout chip design in progress • Backed by detailed simulation Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  10. Scintillator DHCal • Proven technology • Somewhat larger cells • Cheap production by in-house extrusion • MANY options for fiber routing, surface treatment, groove shape, transducer tested with encouraging results • Cosmic ray prototype stack ~ready • Bolstered by extensive simulation Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  11. GEM DHCal • New technology • Double-gap • First prototype w/electronics assembled, operational • Initial tests with CR, source at par with results shown by developers • Multichannel prototypes under construction • Backed up by extensive simulation Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  12. Scint. HCal (analog) • Similar to Scint DHCal, but ~2.5 times larger tiles • Improve lateral resolution by staggering • Cell prototyping done • Stack prototype next • Simulation studies in progress Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  13. Particle-flow algorithms • Several calorimeter groups are deeply involved in simulation and software development as well as PFA development (NIU, ANL, Colorado, UTA, …) • First jet reconstruction results are most encouraging, prompting us to more realistic simulations and sophisticated reco algorithms • Much effort invested Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  14. Muon & PID Summary R. Wilson – CSU: Particle ID Software Infrastructure • Embedding PID in the overall LCD/JAS s/w infrastructure? • Fast Simulation/Reconstruction : dE/dx tool; code checks; muon fast simulation. • Cross subsystem PID. A. Maciel – NIU: Simulation Software Development • Extension of generalized and universal simulation framework – new worldwide effort. • Planar muon detector example with 45o strips. Big advance! u vs. v for 2 tracks Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  15. Muon & PID Summary (cont.) C. Milstene – NIU: Muon ID Software Development • Resurrection of m code. • Verification of M. Piccolo’s muon ID for single particles and b-b events. G. Fisk – Fermilab: Scintillator Muon Detector Prototype Planes: Description • General description of scintillator strip layout. M. Wayne – UND: Fiber Connections & Routing • Discussion of fiber associated with bringing the WLS light out of the scintillator strips and onto a multi-anode photomultiplier. Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  16. Muon & PID Summary (cont.) P. Karchin – WSU: MAPMT Readout and Calibration Issues • Test results on Hamamatsu M-16 multi-anode PMT. Calibration ideas. R. Wilson – CSU Geiger Photodiode Array Readout Test • Description of tests performed on prototype APD (avalanche photo-diode). M. Piccolo – INFN RPC Prototype Design Issues • First test results for new glass RPCs. • Rate capability studies • Test Beam at Frascati Plateau curve Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

  17. Prototype Module Layout 5.0 m 2.5m 43 full strips 43 short strips 3.6m (L) x 4.1cm (W) x 1cm (T) 3.6m => 0m long Read out: both ends of full strips; one end of short strips (except the shortest 22). 2*(43 + 21) fibers/side =128 channels = 8 (1.2mm dia) fibers/pix * 16(4 x 4mm2) pixels => Equivalent of One MAPMT/prototype plane Calorimetry + muon/p-id summary LC workshop, Cornell, 16 July, '03

More Related