KDAC QUALITY CONTROL. C-100 HVAC MODULE EVA SENSOR Malfunction. Feb .21. 2011. C-100 EVA SENSOR Malfunction. Frozen at A/C tube . 1. Problem definition . #1. #2. Vehicle: Winstorm Part name: EVA Sensor Description : Icing occurrence Occurrence&Date: WARRANTY (CKD @GM-UAE)

Download Presentation

KDAC QUALITY CONTROL

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Kdac quality control

KDAC QUALITY CONTROL

C-100 HVAC MODULE EVA SENSOR Malfunction

Feb .21. 2011


Kdac quality control

C-100 EVA SENSOR Malfunction

Frozen at A/C tube

1. Problem definition

#1

#2

  • Vehicle: Winstorm

  • Part name: EVA Sensor

  • Description : Icing occurrence

  • Occurrence&Date: WARRANTY (CKD @GM-UAE)

  • Quantities: 2pcs(2/9, received)

▣ Vehicle information


Kdac quality control

C-100 EVA SENSOR Malfunction

2. Returned part analysis

▣ Basic performance test (Resistance value check @0℃,25℃,50℃)


Kdac quality control

C-100 EVA SENSOR Malfunction

2. Returned part analysis

▣ X-Ray Analysis(#1)

① Thermistor chip: OK

② Wire soldering: OK

Terminal & Wire : OK

▣ X-Ray Analysis (#2)

① Thermistor Chip: OK

② Wire soldering: OK

Terminal & Wire : OK

3. Conclusion

  • No Trouble Found (Resistance value OK , X-Ray OK)