ICC - EGSE, PCSS, HCSS, IEGSE -. Otto H. Bauer MPE Garching. Major Goal : Sm ooth T ransition between Mission Phases. EGSE/HCSS Set-up for ILT. AVM-ILT in the PACS Lab. ICC (I). ICC Meeting at MPE, June 26/27 and Oct 7/8: Major topics: Analysis results of Ge:Ga six-pack data

Download Presentation

ICC - EGSE, PCSS, HCSS, IEGSE -

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Icc egse pcss hcss iegse

ICC - EGSE, PCSS, HCSS, IEGSE -

Otto H. Bauer

MPE Garching

PACS ICC


Major goal sm ooth t ransition between mission phases

Major Goal: Smooth Transition between Mission Phases

PACS ICC


Egse hcss set up for ilt

EGSE/HCSS Set-up for ILT

PACS ICC


Avm ilt in the pacs lab

AVM-ILT in the PACS Lab

PACS ICC


Icc i

ICC (I)

  • ICC Meeting at MPE, June 26/27 and Oct 7/8: Major topics:

    • Analysis results of Ge:Ga six-pack data

    • Discussion of Calibration Implementation Procedures (CIPS), corresponding Test Procedures and Command Sequences

    • ´Godfather´principle: ICC members become familiar with hardware

  • Scientific Simulator WG

    • Revision of design and architecture, link to HCSS framework

    • S/C attitude and telescope emissivity and thermal noise included

    • Chopper commands and spatial sampling added

    • Complete chain for blue photometer is ready, red part under test

PACS ICC


Icc ii

ICC (II)

  • Commanding WG

    • AVM-ILT: Definition of on-board control procedures, test procedures and related IA/QLA requirements ongoing

  • EGSE WG

    • Improvements to TestControl to be compliant with CCS environment at Astrium

    • Discussion on Instrument EGSE hardware (to be delivered to Astrium) with HIFI and SPIRE

  • Operations WG

    • Support of test activities

    • Analysis of Ge:Ga six-pack data

PACS ICC


Instrument overview and subsystem responsibilities

Instrument Overview and Subsystem Responsibilities

PACS ICC


Test equipment and ogse overview

Test Equipment and OGSE: Overview

PACS ICC


Cqm ilt programme blue means range of parameter settings reduced or test modified

F1.1FPU integration with test cryostat and OGSE3, alignment

F1.2Electrical continuity check

F1.3Functional test exercising all mechanisms, temperature sensors, sources and detector array read-outs

F1.4Cool down to LHe

F1.5Functional test exercising all mechanisms, temperature sensors, sources and detector array read-out

Q2.1FPU Thermal behaviour

Q2.2Focus definition

Q2.3Relative alignment check spectrometer vs. photometer arrays after vibration respectively thermal cycling

Q2.4sensitivity

Q2.5spatial performance

Q2.6spectral performance

E1.1 Instrument EMC tests

C3.1Absolute fluxcalibration, linearity

C3.2Flat field

C3.3Point spread function

C3.4Distortion, grating alignment

C3.5Relative Spectral Response Funct.

C3.6Wavelength-calibration using TUFIR replaced by vapour absorption cell

C3.7Instrumental profile (grating) measured with TUFIRreplaced (however, some initial profile information from absorption line measurements are planned.

C3.8Ghosts (search for spectral ghosts) TUFIR only, maybe Ge laser?

(C3.9)Stray light (ghosts) with Ge laser?

C3.10Detector time response, stability

(C3.11) Definition of PACS pass bands with TUFIR (not possible with Ge laser)

(C3.12) AOT try out

CQM ILT Programme("Blue" means range of parameter settings reduced or test modified)

PACS ICC


Calibration wg

Calibration WG

  • Compilation and release of PCD draft 7

    • CIP´s and CAP´s for functional tests of Ge:Ga detectors

    • First ideas how to include proton irradiation measurements from tests at UCL-CRC

    • More details on tests of internal calibration sources

  • AOT design

    • Preparation of AOT´s for photometer

    • TN on spectrometer AOT´s

  • Work on spatial calibrators

    • HiRes images for stellar and extragalactic fields

    • Astrometric alignment on 2MASS images

CAP = Calibration Analysis Procedure

CIP = Calibration Implementation Procedure

PCD = PACS Calibration Document

PACS ICC


Icc egse pcss hcss iegse

PACS ICC


Completed test descriptions and command scripts

Completed Test Descriptions and Command Scripts

Requirements CIP/CAP TIP/TAP Tcl IA

Spectrometer

Functional tests (F1.x, F2.x)

Performance tests (P2.x)

Calibration measurements (C3.x)

12

6

17

5

6

16

4

6

13

2

6

14

2

0

2

Most missing spectrometer scripts are in progress, in part pending due to missing technical information

Requirements CIP/CAP TIP/TAP Tcl IA

Photometer

Functional tests (F1.x, F2.x)

Performance tests (P2.x)

Calibration measurements (C3.x)

15

6

11

1

4

9

0

1

6

0

0

6*

0

0

1

* not complete

Many photometer scripts are pending due to missing technical information, situation slowly improving now

PACS ICC


Current pcss functionalities i

Current PCSS Functionalities (I)

  • Quick-Look Analysis QLA: monitoring of signals in Photometer and Spectrometer pixels

    • Offline on stored telemetry or decompressed data

  • Preparation of detector selection tables for uplink via GUI Inspect Telemetry and Telecommand Packets:

    • Automatically propagated from the MIB definitions

    • Overview of types, number of packets and parameters in the packet sequence

    • Selection on type, header fields and any telemetry measure in the packets

    • Extraction of telemetry measures into Tables for convenient plotting, trend analysis, operations, save/restore, export

  • Decompression of science data

    • Telemetry Packets to Data Frames

      • reduced signals, DMC headers and selected raw data

    • Access to signals, samples and DMC headers as Tables and Measures for plotting, visualization, fitting, etc…

  • Import of component level CRE/photoconductor data into same structures

    • of Tables (automatic labeling, inc. units) and on some primitive arrays

    • Labels, zooming, hardcopy, plotsymbols, ...

PACS ICC


Current pcss functionalities ii

Current PCSS Functionalities (II)

  • Inspection of raw and reduced detector signals

    • Statistics on datasets (max, min, mean, median, RMS, sum, ….)

    • Polynomial fitting on datasets (e.g. integration ramps)

    • Some functions (FFT, Convolutions)

  • Plotting

    • of Tables (automatic labeling, inc. units) and on some primitive arrays

      • Labels, zooming, hardcopy, plotsymbols, ...

  • Store the History of your session, edit it and rerun it

  • Write your own data reduction scripts in jython

    • starting from templates and examples

  • Define Tables or other data structures to hold intermediate results or CAP results (Calfiles), populate them, save/restore as fits, exchange them

  • Export any dataset to FITS

PACS ICC


Current pcss functionalities iii

Current PCSS Functionalities (III)

  • Improved support of CRE Data analysis

  • Interface to OBSW development

  • Image dataset (image, WCS) + viewer + operations

  • Image cube dataset + viewer + operations

  • Spectrum dataset + viewer + operations

  • Select/where on tables and Data

  • HK correlation with Science Data

  • QLA running on near real-time telemetry stream

  • MIB Calibration curves applied on housekeeping measures

  • More functions and optimization algorithms

  • Access to PACS operational Database

  • Data rate monitor

  • Use simulator data to test reduction scripts / CAPS

  • Access to instrument properties (e.g. Calibration source spectrum/cube, detector numbering) for different instrument models / configurations

  • Improved User Documentation

  • Optimization for Decompression

  • IDL Bridge implementation

  • Intensive User <-> developer ‘workshops’ with immediate implementations of missing functionalities

  • IA Processes as plug ins into QLA : BG Subtraction, Averaging, …

  • TC to TM verification framework

  • Version control for Detector Selection Tables

PACS ICC


Overall herschel s c test configuration

OVERALL HERSCHEL S/C Test Configuration

PACS ICC


Iegse for ist

IEGSE for IST

OOL

TCH

PACS ICC


Iegse ccs plm dpu i f tests

IEGSE, CCS/PLM – DPU I/F Tests

  • IEGSE

    • H/W configuration under discussion between 3 instruments

    • CCS - IEGSE I/F tests: Router, SCOS 2000, TOPE, Test Control: end March 04 at Astrium, Ottobrunn

  • DPU 1553 I/F test:

    • Contract with Satellite Services, NL: test of physical layers (MIL 1553B) at MPE, first week of December: 6k€

    • CCS/PLM – DPU+SPU, DECMEC Simulators: test at Astrium, Ottobrunn, second week of December, supported by Satellite Servives

PACS ICC