CLX-6240FX & CLX-6200FX series Firmware. Revision History. V0.1 : 2007.06.20 : Initial Release – Joong Mok Lee Revision : to Now - Won Young Chi. Overview - I. Model CLX-6200ND : DADF, HDD option, wireless LAN option CLX-6200FX : ADF, FAX

Download Presentation

CLX-6240FX & CLX-6200FX series Firmware

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Clx 6240fx clx 6200fx series firmware

CLX-6240FX & CLX-6200FX series

Firmware


Revision history

Revision History

  • V0.1 : 2007.06.20 : Initial Release – Joong Mok Lee

  • Revision : to Now - Won Young Chi


Overview i

Overview - I

  • Model

    • CLX-6200ND : DADF, HDD option, wireless LAN option

    • CLX-6200FX : ADF, FAX

    • CLX-6210FX : DADF, FAX, HDD option, wireless LAN option

    • CLX-6240FX : DADF, FAX, HDD, wireless LAN option

  • Print method

    • Single-pass printing (Y->M->C->K)

  • Printing speed

    • CLX-62x0  20/20 ppm (Color/Mono)

    • CLX-6240  20/20 ppm (Color/Mono)

  • Resolution in printing (PC printing)

    • Best mode 1200 x 1200 dpi

    • Normal mode 1200 x 600 dpi

    • Draft mode 600 x 600 dpi

  • Resolution in printing (Copy)

    • Default 600 x 600 dpi

    • Platen photo 1200 x 1200 dpi

  • Duplex mode support


Overview ii

Overview - II

  • Memory size (default)

    • CLX-62x0 : 128MBytes

    • CLX-6240 : 256MBytes

  • Panel

    • 2- line LCD panel support

    • Ten key, speed dial support

    • STOP, Start (Color/Mono) Key

  • Supported I/O port

    • USB, Network

  • CRUM

    • C/M/Y/K Toner, PTB


Overview iii

Overview - III

  • CPU (CLX-62x0/CLX-6240)

    • Type : CHORUS3/SPGPXm (ARM 920EJ /PMC 7065)

    • Speed : 300MHz/533MHz

    • Bus speed : 120MHz/ 120MHz

    • One chip solution (HPVC, I/O, JBIG, network …)

  • Real-Time OS (CLX-62x0/CLX-6240)

    • pSOS (V2.5) / VxWorks 5.5.1

  • Network configuration

    • Embedded Network


Rom image

ROM Image

  • ROM image

  • ROM release

    • Boot image

    • ROM image (except boot image)


F w upgrade

F/W Upgrade

  • USB and Network port are used to F/W upgrade

  • Network applications (SWAS, SWS) can be used for network port upgrade

  • Notice :

    In special mode upgrade, kernel waste header information for

    CLX-62x0/CLX-6240.

    You have to check F/W ROM file with MFP set

    (This mode is ONLY service mode, not user mode)


F w upgrade using button

F/W Upgrade – using button

  • F/W Upgrade using USB Port

    • Make sure connecting Printer to the computer with a USB cable

    • Upgrade in Ready mode

      • Send ROM image file via USB cable in Ready mode

    • Upgrade in Special mode

      • Power ON with pressing ‘STOP key’ two times

      • Change LCD message ‘Wait Image’

      • Send ROM image file via USB cable


F w upgrade using sws

F/W Upgrade – using SWS

  • F/W upgrade using SWS(SyncThru Web Service)

    • Home -> Maintenance -> Firmware Upgrade

1

2

3


F w upgrade using swas

F/W Upgrade – using SWAS

1. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Home  Maintenance


F w upgrade using swas1

F/W Upgrade - using SWAS

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Firmware Upgrade  Upgrade (check device using IP address)

1

2

3


F w upgrade using swas2

F/W Upgrade - using SWAS

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware upload (register firmware)

1

2

3


F w upgrade using swas3

F/W Upgrade - using SWAS

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware Upload (upload firmware)

1

2

3

4


F w upgrade using swas4

F/W Upgrade - using SWAS

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware Upload (confirm uploaded firmware)

1

2

3


F w upgrade vi

F/W Upgrade - VI

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware Upgrade -> Upgrade (choose firmware)

1

2

3


F w upgrade vi1

F/W Upgrade - VI

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware Upgrade -> Upgrade (choose firmware)

1

2

3


F w upgrade using swas5

F/W Upgrade - using SWAS

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware Upgrade -> Upgrade

1

2

3

4


F w upgrade using swas6

F/W Upgrade - using SWAS

2. F/W upgrade using SWAS(SyncThru Web Admin Service)

  • Maintenance -> Firmware Upgrade -> Upgrade (Done)

1

2

3


Information print

Information print

  • Demo page

    • Press OK Key for 2sec

    • Blinking Green LED (status LED)

  • System Configuration page

    • Menu  System Setup  report  configuration  ‘yes’

    • Blinking Green LED (Status LED)

  • Network Configuration page

    • Menu  System Setup  report  Network Info.  ‘yes’

    • Menu  Network  Network Info.  ‘yes’

    • Blinking Green LED (Status LED)


Supplies information

Supplies Information

  • Total Page Count (Color/Mono)

  • Page Count (C/M/Y/K)

  • Fuser Life

  • Toner Remains Percent (C/M/Y/K)

  • Transfer Belt Life

  • Tray1/Tray2 Roller Life

  • MP Roller Life

  • Model ID (C/M/Y/K/PTB)

  • Serial No. (C/M/Y/K/PTB)

  • Product Date (C/M/Y/K/PTB)

  • Last Used Date

  • First Installed Date

  • ADF Scan Page Count

  • Platen Scan Page Count

  • Consumables Information (C/M/Y/K)


Status monitor

Status Monitor

  • Display in Status Monitor window

  • Consumables Life Errors

    • Toner Low

    • Toner empty

    • Replace Toner Cartridge

    • Replace transfer belt soon

    • Replace transfer belt

    • Replace fuser soon

    • Replace fuser

    • Replace imaging unit soon

    • Replace imaging unit

    • Replace Pickup (tray1/tray2) roller

  • Need to replace those items when replace error is indicated


Consumable unit activity

Consumable Unit Activity

  • Toner Empty Status should be selected option as below:

  • - Color : Stop, Continue, Mono Only

  • Mono : Stop, Continue

  • *Stop  all printing is not allowed.

  • *Continue  all printing is allowed until toner cartridge is exhausted.

  • *Mono Only  color printing data is wasted. Mono printing only allowed.

  • Invalid/Install Toner Status

  • Color/Mono/PTB : all printing operation is not allowed.

  • Exhausted Toner Status (After Empty Status)

  • Color/Mono : all printing operation is not allowed.


Clx 6240fx clx 6200fx series firmware

Lily (CLX-62x0)

Part. II Engine F/W


Edc mode

EDC Mode

  • Method to enter

    • Power – On the printer, and wait until the “READY” message appearing on LCD Panel.

    • Push button like next time “Menu -> Stop -> Left arrow -> Back -> OK -> Right arrow”

    • “COMPONEMT TEST Press Menu Key”


Clx 6240fx clx 6200fx series firmware

  • Keys


Clx 6240fx clx 6200fx series firmware

EDC Menu

0. Cover Status


Clx 6240fx clx 6200fx series firmware

Cont.

  • 1. Sensor Status


Clx 6240fx clx 6200fx series firmware

Cont.

  • 2. Motor Test


Clx 6240fx clx 6200fx series firmware

Cont.

  • 3. Fan Test


Clx 6240fx clx 6200fx series firmware

Cont.

  • 4. Clutch/Sol.


Clx 6240fx clx 6200fx series firmware

Cont.

  • 5. Fuser Ctrl


Clx 6240fx clx 6200fx series firmware

Cont.

  • 6. LSU Control


Clx 6240fx clx 6200fx series firmware

Cont.

  • 7. DEV Control


Clx 6240fx clx 6200fx series firmware

Cont.

  • 8. Reset Param

( Take care of this menu because all color regi. data is initialized.)


Clx 6240fx clx 6200fx series firmware

Cont.

  • 9. PrintTest


Error list and recovery

Error list and recovery

  • Operating Error

    • Paper Jam

      • MP(Tray1, Tray2) Paper Jam0

        • When feed sensor is not checked in limit-time after Pick- up

        • Right Cover Open /Close (check Feed Sensor and Pick-up solenoid)

      • Paper Jam1 Open/Close Door

        • When exit sensor is not checked in limit-time after Feed - In

        • Right Cover Open-> remove the paper-> cover close

          (check Feed Sensor , Exit sensor and fuser motor)

      • Paper Jam2 Check Inside

        • When exit sensor is not checked in limit-time after Exit-In

        • Right Cover Open-> remove the paper-> cover close

          (check the exit sensor)

      • Duplex Jam0 Check Inside

        • When Feed sensor is not checked in limit-time after Exit-Out

      • Reverse Jam0 Check Inside

        • When rev. Swing sensor is not checked in limit-time after Exit-In

      • Reverse Jam1 Check Inside

        • When rev. Exit sensor is not checked in limit-time after Swing-Out


Clx 6240fx clx 6200fx series firmware

Cont.

  • Cover Error

    • Cover Open : Install Transfer Belt message is toggled.

      • When right cover is opened or PTB (Paper Transfer Belt) is not installed

      • Check that PTB is installed

      • Check Right-cover switch, and PTB connector

  • Cassette Out Error

    • Tray1(Tray2) Cassette Out

      • When Tray1- Cassette is out.

      • When tray is dedicated Tray2 in printer – driver and Tray2- Cassette is out.

  • Paper Empty / Paper Mismatch

    • MP(Tray1, Tray2) Paper Empty

      • When dedicated-tray is empty

    • Load A4 In MP(Tray1, Tray2)

      • When paper dedicated in driver is different with paper in tray.

      • Push the ”Stop” key , and documents will be printed continuously


Clx 6240fx clx 6200fx series firmware

Cont.

  • Service Call error

    • LSU Motor Error Cycle Power

      • When lock signal of LSU motor is not checked

      • Check LSU and Main board (check Connector)

    • OPC Motor Locked / Deve Motor Locked

      • When lock signal of BLDC motor is not checked

      • Check Motor and Main board (check Connector)

    • Fuser Error

      • Low Heat Error Cycle Power

        • Fuser temperature is not reached at target temperature in limited time.

      • Over Heat Error Cycle Power

        • When Fuser temperature is more than a over- heat temperature

      • ADC Slope Error Cycle Power

        • Fusing Unit is not heated

      • Thermistor Open/Short Cycle Power

        • Thermistor level is not normal

      • Check Thermistor is not connected , Thermistor is dirty , thermostat is opened


Clx 6240fx clx 6200fx series firmware

Cont.

  • Outer (Inner) Temp. Error Cycle Power

    • Temp. Sensor- level is not normal

  • When color Regi. is not corrected

    • First , Check Toner-Density

    • Second, Check scratch of PTB.


Clx 6240fx clx 6200fx series firmware

Cont.

  • Consumables

    • Install Cyan (Magenta, Yellow, Black) Toner

    • Install Transfer Belt

      • When CRUM Interface is abnormal

      • Extract Consumables from the Printer, and push consumables to the printer again.

    • Invalid Cyan (Magenta, Yellow, Black) Toner

    • Invalid Transfer Belt

      • When CRUM Interface is abnormal

      • Extract Consumables from the Printer, and push consumables to the printer again.


Clx 6240fx clx 6200fx series firmware

The end