Thermal Cycling Tests of Dummy Modules Setup Pre-cycling resistance measurements IZM module results Alenia module underway Setup Modules built with CERN Flex V.2 and bare dummy module. Used Ecobond glue under MCC, pigtail bonding field, and 4 corners.

Related searches for Thermal Cycling Tests of Dummy Modules

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Thermal Cycling Tests of Dummy Modules' - Thomas


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Thermal cycling tests of dummy modules l.jpg
Thermal Cycling Tests of Dummy Modules

  • Setup

  • Pre-cycling resistance measurements

  • IZM module results

  • Alenia module underway


Setup l.jpg
Setup

  • Modules built with CERN Flex V.2 and bare dummy module.

  • Used Ecobond glue under MCC, pigtail bonding field, and 4 corners.

  • Modules used for FE wirebonding tests prior to thermal cycling

  • First cycled modules unconstrained, then attached to sector using CGL and UV-cure tacks on 4 corners.

  • Cycled 21oC to –35oC in environmental chamber.

  • Monitored module temperature and chain resistance in real time


Setup cont l.jpg
Setup (cont.)

Only 4 columns monitored in real time during cycling

W

W

All columns measured on probe station before and after



Izm module results l.jpg
IZM Module results

  • No change after 2 cycles of unconstrained module

  • No change DURING 19 cycles of module on sector

  • Open columns detected AFTER overnight storage at 21oC

On bad chip, all columns were open prior to tests & chip fell off after removing module from sector. Solder bumps left ½ on chip ½ on sensor.

RED = location of open column

32/270 columns failed


Possible explanation l.jpg
Possible Explanation

UV Tack

UV Tack

  • Results are consistent with differential movement of dummy chips and dummy sensor.

  • For example, assume sensor doesn’t move under cooldown(probably not correct, just example), then contraction of each chip is about (2.5x10-6) x(either 3.7 or 5.5x103 microns)x56=0.5-0.8 microns.

  • Worst case is corners of chip, but we only measure columns.

  • Approximate strain is (0.5-0.8)/(20) or 2.5-3.8%.. Solder stress vs strain becomes non-linear for strains above about 1%.

  • Creep rupture is possible explanation for failure after sitting.

Carbon-carbon on sector

CGL


Alenia module tests underway l.jpg
Alenia Module Tests Underway

  • 3 Cycles to –35o unconstrained

  • 3 Cycles to –35o mounted on sector

  • Time at –35o 30-40 minutes/cycle

  • Let sit for a day

  • No failures yet

  • Tests continuing


ad