Food thermometers
Download
1 / 12

Food Thermometers - PowerPoint PPT Presentation


  • 330 Views
  • Updated On :

Food Thermometers. Calibrating Instant-Read Bi-metallic Thermometers Adapted from a presentation prepared by Hospitality & Tourism Management Purdue University. Bi-metallic Stemmed Thermometers. The most common and versatile type

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Food Thermometers' - Samuel


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Food thermometers l.jpg

Food Thermometers

Calibrating Instant-Read

Bi-metallic Thermometers

Adapted from a presentation prepared by

Hospitality & Tourism Management

Purdue University


Bi metallic stemmed thermometers l.jpg
Bi-metallic Stemmed Thermometers

  • The most common and versatile type

  • Measures temperature through a metal probe with a sensor at the end

  • Usually measure from 0°F to 220°F

    • 50F to 550F NOT practical

  • Must be capable of re-calibration

    • Must have an adjustable nut

Adapted from Purdue University, Hospitality & Tourism Management


Bi metallic stemmed thermometers3 l.jpg
Bi-metallic Stemmed Thermometers

  • When selecting this type of thermometer, it should have:

    • An adjustable calibration nut

    • Easy to read numbered temperature markings

    • A dimple to mark the end of the sensing area

    • Accuracy to within ± 2°F (± 1°C)

Adapted from Purdue University, Hospitality & Tourism Management


Rules for using the thermometer l.jpg
Rules For Using the Thermometer

  • Keep the thermometer and its case clean

    • Wash, rinse, sanitize & air dry after every use

  • When measuring an item,

    • insert probe through the thickest part of the item

    • insert deep enough to pass the dimple or sensing area of the thermometer

  • Calibrate regularly to insure its accuracy

Adapted from Purdue University, Hospitality & Tourism Management


When to calibrate l.jpg
When to Calibrate --

  • After dropping the thermometer

  • If shocked by extreme temperature change

  • Periodically, depending on frequency of use.

Adapted from Purdue University, Hospitality & Tourism Management


Calibrating the thermometer l.jpg
Calibrating the Thermometer

  • There are two basic acceptable methods

    • Ice-Point Method

    • Boiling-Point Method

Adapted from Purdue University, Hospitality & Tourism Management


Ice point calibration method l.jpg
Ice-Point Calibration Method

  • Fill a large glass with crushed ice

  • Add tap water to fill glass, stir well

  • Place stem into the ice water

    • sensing area must be completely submerged and not touching the glass

  • Wait at least 30 seconds

    • until the indicator stops moving

Adapted from Purdue University, Hospitality & Tourism Management


Ice point calibration method8 l.jpg
Ice-Point Calibration Method

  • With the thermometer stem still in the water

    • Hold calibration nut secure with pliers/wrenche

  • Carefully rotate thermometer head

    • Until the pointer reads 32°F

      __________________

      (The plastic case that comes with some models has a “hex-hole” built-in - to use instead of a pliers or wrench.)

Adapted from Purdue University, Hospitality & Tourism Management


Ice point calibration method9 l.jpg
Ice-Point Calibration Method

Adapted from Purdue University, Hospitality & Tourism Management


Boiling point calibration method l.jpg
Boiling-Point Calibration Method

  • Bring clean water to a boil in a deep pan

  • Place the thermometer stem into the boiling water

    • sensing area must be completely submerged and not touching the glass

  • Wait at least 30 seconds

    • until the indicator stops moving

  • NOTE: only use for thermometers that start reading above 32°F

Adapted from Purdue University, Hospitality & Tourism Management


Boiling point calibration method11 l.jpg
Boiling-Point Calibration Method

  • With the thermometer stem still in the water

    • Hold calibration nut secure

  • Carefully rotate thermometer head

    • Until the pointer reads 32°F

    • the thermometer head so that the pointer reads 212°F

      __________________

      (The plastic case that comes with some models has a “hex-hole” built-in - to use instead of a pliers or wrench.)

Adapted from Purdue University, Hospitality & Tourism Management


Boiling point calibration method12 l.jpg
Boiling-Point Calibration Method

Adapted from Purdue University, Hospitality & Tourism Management