1 / 2

DynaClip® Bone Fixation System - Product Information | MedShape

DynaClipu00ae Bone Fixation System is an innovative bone staple system from MedShape which offers dynamic stability and post-operative compression in joint fusion and osteotomy procedures including Lapidus fusion, Akin osteotomy, midfoot fusion, and calcaneal osteotomies. Read this file to learn in detail about this unique product. For further product information or to arrange a product demonstration, visit www.medshape.com or call us at 877-343-7016.tttt<br>

Medshape123
Download Presentation

DynaClip® Bone Fixation System - Product Information | MedShape

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EFFICIENT INSTRUMENTATION Universal Procedure Pack Disposable, single-use, sterile kit that contains ALL instruments needed to prepare the fusion site. No need to open multiple packs! 3 5 1 4 2 1 - 2 mm Drill 2 - 3 mm Drill 3 - 2 mm Locator Pins 4 - 3 mm Locator Pins Slide 5 - Universal Drill Guide Body • Serves as both implant sizer AND drill guide • Compatible with ALL size offerings by using adjustable Slide PRODUCT INFORMATION • Ergonomic, low-profile handle to maximize visibility of fusion site. Drill Sleeves DYNACLIP IMPLANTS & SINGLE USE INSTRUMENTS Part No. Description For further product information or to arrange a product demonstration, please contact your local MedShape representative or call Customer Service at 877-343-7016. You can also visit www.medshape.com. 3000-00-080808 DynaClip, 8 mm x 8 mm x 8 mm 3000-00-101010 DynaClip, 10 mm x 10 mm x 10 mm 3000-00-121212 DynaClip, 12 mm x 12 mm x 12 mm 3000-00-141414 DynaClip, 14 mm x 14 mm x 14 mm 3000-00-181818 DynaClip, 18 mm x 18 mm x 18 mm MedShape, Inc. 1575 Northside Drive, NW Suite 440 Atlanta, GA 30318 T: 877-343-7016 F: 877-343-7017 3000-00-182020 DynaClip, 18 mm x 20 mm x 20 mm 3000-00-201818 DynaClip, 20 mm x 18 mm x 18 mm 3000-00-202222 DynaClip, 20 mm x 22 mm x 22 mm 3000-00-262020 DynaClip, 26 mm x 20 mm x 20 mm 3000-01-000 Universal Procedure Pack, Sterile DYNAMIC STABILITY WITH NEXT-GENERATION STRENGTH CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. ©MedShape, Inc., 2018. All rights reserved. Printed in the USA. Pat: http://www.medshape.com/patents.html Other U.S. and International Patents Pending. MK-10168 Rev 00. Issued 10/2018. DynaClip is a trademark of MedShape, Inc. All other trademarks are trademarks of their respective owners or holders.

  2. THE PROOF IS IN THE SCIENCE NEXT-GENERATION STRENGTH DESIGNED TO CLIP THE COMPETITION Superior Bending Strength When subjected to static 4-point bending, the DynaClip is at least 66% stronger compared with a competitor NiTiNOL staple across the range of size offerings.1 The DynaClip’s versatile design and numerous size offerings allow for its use in a variety of procedures including: Low-profile continuous cross section along entire bridge 24o of bridge curvature to maximize compression Broad bridge design provides additional stiffness and durability 1. Akin Osteotomy 2. Chevron Osteotomy 3. Lapidus Fusion 4. Talonavicular Fusion 5. Calcaneocuboid Fusion 6. Tarsometatarsal Fusion Superelastic NiTiNOL construction allows for dynamic post-operative compression Variable length teeth cut into legs for improved pullout resistance DYNACLIP INSERTER • Pre-loaded on disposable inserter • Fast, Easy Deployment. No Twisting! Testing performed per ASTM F564. Values represent mean +/- standard deviation, *p<0.05 vs. FuseForce of same size. Strike surface DESIGN RATIONALE Dependable Durability Finite Element Analysis under 3-Point Bending When subjected to cyclic 4-point bending at the same force, the Dyna- Clip is able to resist implant failure for 6X more loading-unloading cycles compared with a competitor NiTiNOL staple across the range os size offerings.1 DynaClip™ Competitor staples have either a thin bridge or broad bridge with thin legs which place all stresses on the staple corner, increasing the likelihood for implant failure. Strains distributed uniformly through bridge Competitor Staples Minimal deformation in legs Strains concentrated at corner where bridge transitions to leg Low profile to ensure visibility of fusion site Built-in tamp Thanks to a unique manufacturing method, the DynaClip’s patent-pending design evenly distributes stresses across the bridge, thereby ensuring reliable, long term stability post-surgery. Testing performed per ASTM F564. Values represent mean +/- standard deviation, *p<0.05 vs. FuseForce of same size. 1 Data on File, MedShape, 2018.

More Related