Perchlorate. An Integrated Approach to Ensure Reliable Perchlorate Analytical Results. April 14, 2004. Agenda. Perchlorate Chemistry and Sources Current Methods for Testing Ion Chromatography LC/MS/MS An Integrated Approach A Success Story Summary and Conclusions. Perchlorate Ion.

Download Presentation

Perchlorate

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Perchlorate l.jpg

Perchlorate

An Integrated Approach to Ensure Reliable Perchlorate Analytical Results

April 14, 2004


Agenda l.jpg

Agenda

  • Perchlorate Chemistry and Sources

  • Current Methods for Testing

  • Ion Chromatography

  • LC/MS/MS

  • An Integrated Approach

  • A Success Story

  • Summary and Conclusions


Perchlorate ion l.jpg

Perchlorate Ion

  • Perchlorate is a compound containing one chlorine atom and four oxygen atoms.

  • Perchlorate is an ion, meaning it carries an electrical charge, as indicated by the negative sign.


Natural sources of perchlorate l.jpg

Natural Sources of Perchlorate

  • Chilean fertilizer deposits

  • New Mexican potash

  • Canadian potash

  • Californian hanksite

  • Bolivian playa crusts


Anthropogenic sources of perchlorate l.jpg

Anthropogenic Sources of Perchlorate

  • Rocket Fuel

  • Fireworks

  • High explosives

  • Flares

  • Herbicides

  • Automobile airbags

  • Tracer munitions

  • Detergents ?


How is perchlorate measured l.jpg

How is perchlorate measured?

  • EPA Method 314.0

    • Ion chromatography/conductivity detector

  • Enhanced (Modified) 314.0

    • Suppressed Conductivity Detector

  • SW-846 Method 9058 (draft)

    • Ion Chromatography/conductivity detector


How is perchlorate measured7 l.jpg

How is perchlorate measured?

  • Other analytical methods that can detect perchlorate:

    • IC “Improved” Method 314.1 approved use of 2nd column confirmation and pre-concentration of samples.

    • IC/MS (ion chromatography/mass spectrometry) Proposed Method 330.0

    • LC/MS (liquid chromatography/mass spectrometry)

    • LC/MS/MS (liquid chromatography/mass spectrometry/mass spectrometry) Method 8321 Modified, Proposed Method 331.0


Ion chromatography l.jpg

Ion Chromatography


Ion chromatography9 l.jpg

Ion Chromatography

  • An aqueous sample, comprised of components A and B, is injected into the ion chromatograph.

  • The sample enters the analytical column which is packed with a material that can adsorb the components of the sample.

  • Some components are more strongly adsorbed.

Diagram from Fundamentals of Analytical Chemistry, Skoog, 1988.


Ion chromatography10 l.jpg

Ion Chromatography

  • Fresh solvent is continuously injected into the instrument.

  • The solvent carries the sample components, A and B, through the column.

  • Component B is more strongly adsorbed onto the column and is moving thought the column at a slower rate.

  • The boundary between A and B is indistinct at this point.

Detector

Diagram from Fundamentals of Analytical Chemistry, Skoog, 1988.


Ion chromatography11 l.jpg

Ion Chromatography

  • Component B is almost completely separated from component A.

  • The boundary between the two components is more distinct.

Detector

Diagram from Fundamentals of Analytical Chemistry, Skoog, 1988.


Ion chromatography12 l.jpg

Ion Chromatography

  • Component B is completely separated from component A.

  • Component A exits the column through the detector at time t3.

  • The detector records component A as a peak (pictured below the column) in the sample chromatogram (graph).

Detector

Diagram from Fundamentals of Analytical Chemistry, Skoog, 1988.


Ion chromatography13 l.jpg

Solvent

Ion Chromatography

  • Component B exits the column through the detector at time t4.

  • The detector records component B as a peak (pictured below the column) in the sample chromatogram.

Detector

Diagram from Fundamentals of Analytical Chemistry, Skoog, 1988.


Slide14 l.jpg

Diagram from Fundamentals of Analytical Chemistry, Skoog, 1988.


Identification of perchlorate by ion chromatography l.jpg

Identification of Perchlorate by Ion Chromatography

11.2.4The width of the retention time window used to make identifications should be based upon measurements of actual retention time variations of standards measured over several days. Three times the standard deviation of retention time may be used as a suggested window size but the retention time window should not extend beyond ± 5% of the retention time for perchlorate. The experience of the analyst should weigh heavily in the interpretation of these chromatograms.

EPA Method 314.0


Ic perchlorate standard l.jpg

IC Perchlorate Standard


High conductivity l.jpg

High Conductivity


Carry over l.jpg

Carry Over


Matrix spike confirmation l.jpg

Matrix Spike Confirmation


Matrix spike non confirmation l.jpg

Matrix Spike Non- Confirmation


Matrix spike non confirmation21 l.jpg

Matrix Spike Non- Confirmation


Liquid chromatography mass spectrometry mass spectrometry l.jpg

Liquid Chromatography/MassSpectrometry/Mass Spectrometry


Lc ms ms l.jpg

LC/MS/MS

  • Leading edge technology

  • DoD Recommended

  • Pending Regulatory Approval


Api ms ms l.jpg

API MS/MS


Bowling balls and feathers a simplification of mass spec separations l.jpg

Bowling Balls and Feathers: a simplification of mass spec separations


Identification by lc ms ms l.jpg

Identification By LC/MS/MS

  • Liquid chromatography separates perchlorate from other sample components in the same manner that ion chromatography does

  • Mass spectrometers (MS) are used as detectors in place of the conductivity detector used in IC.

  • Unlike conductivity detectors, an MS is a specific detector


Detection by lc ms ms l.jpg

Detection By LC/MS/MS

  • The MS counts the number of ions that have a specific molecular weight. Perchlorate has a characteristic molecular weight (MW).

  • The first MS counts the number of ions that have the MW of perchlorate: 1 Chlorine (35) + 4 Oxygens (16) = 99

  • The second MS removes one of the oxygen atoms and then counts the number of “daughter” ions that have that MW: 1 Chlorine (35) + 3 Oxygens (16) = 83

  • Chlorine has a less abundant isotope (MW 37), so ions with MW 101 are also counted by the first MS and ions with MW 85 are counted by the second MS.

  • The retention time of the peak for MW 99 must be the same as the retention time of the peak for MW 83 for perchlorate to be confirmed. If the retention times are different, then the two molecular weight were detected from two different components and perchlorate is not confirmed.


Non detect analysis by lc ms ms l.jpg

Non-detect Analysis by LC/MS/MS

Analysis by LC/MS/MS

  • Reporting limit is 2 g/L.

  • Bottom chromatogram shows the counts of ions with molecular weight 83 (1 chlorine + 3 oxygens).

  • Top chromatogram shows the counts of ions with molecular weight (the isotope of chlorine).

  • Perchlorate is not detected.


Comparison of lc ms ms l.jpg

Comparison of LC/MS/MS

Non-Detect

Detect


Detect analysis by lc ms ms l.jpg

Detect Analysis by LC/MS/MS

  • Reporting limit 2 g/L.

  • Bottom left shows MW 83 (1 chlorine + 3 oxygens).

  • Top left shows MW 85 (the isotope of chlorine).

  • Right chromatogram show the 18O internal standard (recovery 88%).

  • Perchlorate is detected.


Perchlorate decision tree l.jpg

Perchlorate Decision Tree


Success using the perchlorate decision tree l.jpg

Success Using the Perchlorate Decision Tree

  • Approximately 1000 samples were collected and analyzed for perchlorate from August 2003 through January 2004.

  • 89 samples (about 9% of total) were pretreated and reanalyzed.

  • 39 samples (about 3% of total) were reanalyzed by LC/MS/MS - 24 detects and 15 nondetects.

  • 10 perchlorate detects (about 0.4% of total) were confirmed by LC/MS/MS – 58% false positive rate and a 0% false negative rate.


Summary l.jpg

Summary

  • Why use 314.0?

    • Cost

    • Capacity

    • Availability

    • Promulgated Methods

  • When to use LC/MS/MS?

    • Definitive Data

    • Critical Samples

    • Small Projects