2009 Uniform Plumbing Code Presentation. Purpose. To review the contents, exemptions, exclusions and amendments pertaining to the newly adopted 2009 Uniform Plumbing Code as the Maine State Internal Plumbing Code. . Obtaining a 2009 Uniform Plumbing Code.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about '2009 uniform plumbing code presentation' - JasminFlorian


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

Purpose l.jpg
Purpose

  • To review the contents, exemptions, exclusions and amendments pertaining to the newly adopted 2009 Uniform Plumbing Code as the Maine State Internal Plumbing Code.


Obtaining a 2009 uniform plumbing code l.jpg
Obtaining a 2009 Uniform Plumbing Code

  • International Association of Plumbing and Mechanical Officials

  • 4755 E. Philadelphia Street

  • Ontario, CA 91761-2816

  • Telephone 909-472-4100 or 1-800-85-IAPMO

  • www.iapmo.org


Web address to the plumbers examining board rules l.jpg
Web address to the Plumbers’ Examining Board Rules

  • www.maine.gov/professionallicensing

  • List of professions

  • Plumbers

  • Laws and rules

  • Rules chapter 4 Installation Standards


Overview statement l.jpg
Overview Statement

  • The Maine State Internal Plumbing Code shall be the 2009 Uniform Plumbing Code, with amendments and exclusions.

  • Amendments and exclusions to the Maine State Internal Plumbing Code will be provided in Chapter 4 of the Plumbers’ Examining Board Rules.


Overview continued l.jpg
Overview continued

  • Chapter 1, 103.8.2. Wherever in this code reference is made to an appendix, the provisions in the appendix shall not apply unless specifically adopted.

  • The appendices are intended to supplement the provisions of the installation requirements of this code.


Chapter 1 l.jpg
Chapter 1

  • Chapter One has been expanded and now includes:

  • 101.3 Plans Required

  • 101.4 Scope

  • 101.4.1.1 Repairs and Alterations

  • 101.5 Application to Existing Plumbing Systems

  • 102.2 Duties and Powers of the Authority Having Jurisdiction

  • 103.5 Inspections

  • 103.5.3 Testing of Systems


Chapter 2 definitions l.jpg
Chapter 2Definitions

a. The board does not adopt Chapter 205.0, Confined Space.

  • b. The board does not adopt Chapter 207.0 Excess Flow Valve (EFV).

  • c. The board does not adopt Chapter 208.0, Flammable Vapor or Fumes.

  • d. The board amends Chapter 220.0, Roughing-In, as follows:

  • (i) The installation of all parts of the plumbing system that can be completed prior to the installation of fixtures. This includes drainage, water supply, vent piping, and the necessary fixture supports.

  • e. The board does not adopt Chapter 223.0, Unconfined Space.


Chapter 2 additions l.jpg
Chapter 2 additions

  • 209.0 Gravity Grease Interceptors

  • Grease Interceptors

  • Grease Removal Devices

  • Hydromechanical Grease Interceptor

  • These definitions reflect changes made to the grease interception sections in Chapter 10.


Slide10 l.jpg

New

Water Hammer Arrester – A device to absorb hydraulic shock, either of the air chamber or mechanical device design. A device designed to provide protection against hydraulic shock in the building water supply system.



Chapter 3 general regulations l.jpg
Chapter 3General Regulations

  • a. The Board does not adopt section 313.12.3 Ratproofing

  • b. The board does not adopt 314.7 Hangers and Supports for gas piping.

  • c. The board adopts Chapter 316.2.2, Unions, with the following exception:

  • (i) Approved unions shall be permitted to be used in drainage piping when accessibly located in the trap seal or between a fixture and its trap in the vent system, except underground or in wet vents, and at any point in the water supply system, and in gas piping as permitted by Section 1211.3.2(4).

  • d. The board does not adopt Chapter 320.0, Medical Gas and Vacuum Systems.


Slide13 l.jpg

Figure 3-15 Prohibited or Restricted Fittings

Prohibited Fittings and Practices 311.1




Chapter 4 plumbing fixtures and fixture fittings l.jpg
Chapter 4Plumbing Fixtures and Fixture Fittings

  • Chapter 4 is adopted as written.

  • Changes from the 2000 Maine State Internal Plumbing Code and the 2009 Uniform Plumbing Code include:

  • 402.3.1 Non-Water Urinals-Waterless Urinals

  • 402.4 Metered Faucets-Self Closing Faucets

  • 407.5 Setting (Exceptions)

  • 408.4 Closet rings moved from Chapter 7.

  • 414.5 & 416.3 Limitation of hot water temperature for public lavatories and bidets.

  • 418.0 Shower and Tub-Shower Combination Control Valves shall be of the anti-scald type.

  • Expansion of table 4-1 to include Retail or Wholesale Stores and smaller-type Public or professional buildings.


Slide17 l.jpg

402.3.1 Non-water Urinals

Shall be listed and comply with the applicable standards referenced in Table 14-1. Shall have a barrier liquid sealant to maintain a trap seal.

Shall permit the uninhibited flow of waste through the urinal to the sanitary drainage system. Shall be cleaned and maintained in accordance with the manufacturer’s instructions after installation.

Shall have a water distribution line rough-in to the urinal location to allow for the installation of an approved backflow prevention device in the event of a retrofit.


Slide18 l.jpg

Prohibited Fixtures

405.0

No WC with invisible seal or walls that are not thoroughly washed at each discharge

Trough urinals and urinals with an invisible seal shall be prohibited.

Exception: Non-water urinals.


Slide19 l.jpg

Setting Water Closet 407.5

15" to center from side wall

30" center to center

Set level

24" space in front

Flush-o-meter vacuum breaker 6" above highest part of fixture


Slide20 l.jpg

408.2.2

WC for public use shall be elongated:

For children shall be of suitable size:

Seats:

Smooth non-absorbent

All seats must be open front except within dwelling units

Properly sized for bowl shall conform to the applicable standard referenced in Table l4-1.


Slide21 l.jpg

Setting Urinals 407.5

12" from side wall

24" center to center

Flushometer vacuum breaker critical level minimum 6" above the highest part of the fixture


Slide22 l.jpg

Exception:

The installation of paper dispensers or accessibility grab bars shall not be considered obstructions

:


Slide23 l.jpg

411.7 Minimum size shower 1024 square inches

Exception No. 1:

Showers that are designed to

comply with ICC A117.1

Exception No. 2:

The minimum required area and dimension shall not apply where an existing bathtub is replaced by a shower receptor having minimum overall dimensions of 30 inches (750 mm) in width and 60 inches (1,500 mm) in length.


Slide24 l.jpg

Hot Water Temperature for Public Lavatories 413.1

Hot water delivered from public use lavatories shall be limited to a maximum temperature of 120°F by a device that conforms to ASSE 1070 or CSA B125.3.

The water heater thermostat

shall not be considered a

control for meeting this

provision:


Slide26 l.jpg

Hot Water Temperature 413.1

Average shower = 100° F

Cold shower = 95° F

Hot shower = 105° F

Very hot shower = 110° F

Normal threshold of pain = 118° F

Burning of skin = 122° F


Chapter 5 water heaters l.jpg
Chapter 5 413.1Water Heaters

  • Chapter 5, Water Heaters

  • a. The board only adopts the following two sections of Chapter 5. All other sections of Chapter 5 the board does not adopt.

  • (i) Chapter 506.4, Indirect-Fired Water Heaters, which includes 506.4.1 and 506.4.2.

  • (ii) Chapter 508.0, Other Water Heater Installation Requirements, which includes 508.1, 508.2, 508.3, 508.4 and 508.5.


Chapter 6 water supply and distribution l.jpg
Chapter 6 413.1Water Supply and Distribution

  • Chapter 6 is adopted as written.

  • Changes between the 2000 Maine State Internal Plumbing Code and the 2009 Uniform Plumbing Code include.

  • Expansion of Tables 6-2 & 6-3, backflow prevention devices and 6-4, materials.

  • 605.5 Control valves on parallel water distribution systems.

  • 608.7 Vacuum Relief Valves

  • Tables 6-7 and 6-8


Slide29 l.jpg

601.0 Hot and Cold Water Required. 413.1

In occupancies where plumbing fixtures are

installed for private use, hot water shall be required

for bathing, washing, laundry, cooking purposes,

dishwashing or maintenance. In occupancies where

plumbing fixtures are installed for public use, hot

water shall be required for bathing and washing

purposes. This requirement shall not supersede the

requirements for individual temperature control

limitations for public lavatories, bathtubs, whirlpool

bathtubs and shower control valves.


Slide30 l.jpg

  • TABLE 6-2 413.1

  • Has been expanded to include a new format and additional information:

  • Device, assembly. Or method

  • Applicable standards

  • Pollution (low hazard)

  • Contamination (high hazard)

  • Installation

  • (page 108-109 of the 2009 UPC)


Slide31 l.jpg

  • TABLE 6-4 413.1

  • Has been expanded to include a new format and additional information:

  • Material

  • Building supply and fittings

  • Water distribution pipe and fittings

  • Referenced Standards (Pipe)

  • Referenced Standards (Fittings)

  • (page 115 of the 2009 UPC)


Slide32 l.jpg

605.5 413.1A control valve shall be installed immediately ahead of each water-supplied appliance and immediately ahead of each slip joint or appliance supply. Parallel water distribution systems shall provide a control valve either immediately ahead of each fixture being supplied or installed at the manifold and shall be identified with the fixture being supplied.


Slide33 l.jpg

Section 608.2 Excessive Water Pressure 413.1

(new portion of)

An approved expansion tank shall be installed

in the cold water distribution piping

downstream of each such regulator to prevent

excessive pressure from developing due to

thermal expansion and to maintain the pressure

setting of the regulator. The expansion tank

shall be properly sized and installed in

accordance with the manufacturer’s

instructions and listing.


Slide34 l.jpg

608.7 Vacuum Relief Valves. Where a hot-water storage tank or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.


Slide35 l.jpg

609.10 Water Hammer. or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

Building water supply systems where quick-

acting valves are installed shall be provided

with water hammer arrester(s) to absorb high

pressures resulting from the quick closing of

these valves. Water hammer arrestors shall be

approved mechanical devices in accordance

with the applicable standard(s) referenced in

Table 14-1 and shall be installed as close as

possible to quick-acting valves


Slide36 l.jpg

TABLE 6-8 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

Sizing of Residential Water Softeners

Required Size of Number of Bathroom

Softener Connection Groups Served1

3/4 in. up to 2 (#2)

1 in. up to 4 (#3)

1 Installation of a kitchen sink and dishwasher, laundry

tray, and automatic clothes washer permitted without

additional size increase.

2 An additional water closet and lavatory permitted.

3 Over four (4) bathroom groups, the softener size shall be

engineered for the specific installation.


Chapter 7 sanitary drainage l.jpg
Chapter 7 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.Sanitary Drainage

  • Chapter 7 is adopted as written.

  • Changes between the 2000 Maine State Internal Plumbing Code and the 2009 Uniform Plumbing Code include.

  • Table 7-1 Materials for Drain, Waste, Vent Piping and Fittings.

  • 712.0 Testing Media. Plastic pipe shall not be tested with air.

  • Policy Statement:


Slide38 l.jpg

Plumbers’ Examining Board or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.March 9, 2011Policy StatementThe Plumbers’ Examining Board will allow the testing of plastic schedule 40 (DWV) (drainage, waste, vent) piping systems with 5 psi maximum of air. For safety purposes, when testing with air, an approved 6 psi relief valve is required.Co-extruded ABS and PVC schedule 40 (cellular core) piping systems with referenced standards ASTM F1488 and ASTMF 891 shall not be tested with air.PVC and CPVC building supply and water distribution piping systems shall not be tested with air.


Slide39 l.jpg

  • TABLE 7-1 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

  • Materials for Drains, Waste, Vent pipe and Fittings. New format and Additional information:

  • Underground DWV

  • Aboveground DWV

  • Building Sewer

  • Referenced Standards (pipe)

  • Referenced Standards (fittings)

  • Page 126 of the 2009 UPC.


Slide41 l.jpg

Sumps and Receiving Tanks 710.9 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

Dual pumps in public use occupancies shall have an audio and visual alarm, readily accessible, that signals pump failure or an overload.


Slide42 l.jpg

712.0 Testing. or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

712.1 Media. The piping of the plumbing, drainage, and venting systems shall be tested with water or air. The Authority Having Jurisdiction shall be permitted to require the removal of any cleanouts, etc., to ascertain

whether the pressure has reached all parts of the system. After the plumbing fixtures have been set and their traps filled with water, they shall be submitted to a final test.


Chapter 8 indirect wastes l.jpg
Chapter 8 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.Indirect Wastes

  • Chapter 8 can be adopted as written.

  • There are no major changes between the 2000 Maine State Internal Plumbing Code and the 2009 Uniform Plumbing Code.

  • Point of concern:

  • 814.0 Condensate waste and disposal


Slide44 l.jpg

811.2 Each waste pipe receiving or intended to or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

receive the discharge of any fixture into which acid or corrosive chemical is placed, and each vent pipe

connected thereto, shall be constructed of Chlorinated Poly(vinyl-chloride) (CPVC), Polypropylene (PP), Polyvinylidene Fluoride (PVDF), chemical-resistant glass, high-silicon iron pipe, or lead pipe with a wall thickness of not less than one-eighth (1/8) inch (3.2 mm); an approved type of ceramic glazed or unglazed vitrified clay; or other approved corrosion-resistant materials.


Chapter 9 vents l.jpg
Chapter 9 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.Vents

  • a. The board adopts Chapter 906.0, Vent Terminations, with the following amendments:

  • (i) 906.1. Each vent pipe or stack shall extend through its flashing and shall terminate vertically not less than six (6) inches (152 mm) two (2) feet above the roof nor less than one (1) foot (305 mm) from any vertical surface.

  • (ii) 906.3. Vent pipes shall be extended separately or combined, of full required size, not less than six (6) inches (152mm) two (2) feet above the roof or fire wall. Flagpoling of vents shall be prohibited except where the roof is used for purposes other than weather protection. Vents within ten (10) feet (3,048 mm) of any part of the roof that is used for such other purposes shall extend not less than seven (7) feet (2,134 mm) above such roof and shall be securely stayed.


Chapter 9 vents46 l.jpg
Chapter 9 or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.Vents

  • (iii) 906.7. Frost or Snow Closure. Where frost or snow closure is likely to occur in locations having minimum design temperature below 0°F (-17.8°C), vent terminals shall be not less than two (2) inches (50 mm) in diameters, but in no event small than the required vent pipe. The change in diameter shall be made inside the building not less than one (1) foot (305 mm) below the roof in an insulated space and terminate not less than ten (10) inches (254 mm) two (2) feet above the roof, or as required by the Authority Having Jurisdiction.


Chapter 9 changes l.jpg
Chapter 9 Changes or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

  • 901.2 Trap Seal Protection

  • 908.2 Horizontal Wet Venting for Bathroom Groups

  • 908.2.2 Vent Connection

  • 908.2.3 Size of the wet vent

  • 911.0 Engineered Vent System

  • 911.2 Minimum Requirements of an engineered vent system.


Slide48 l.jpg

901.2 Trap Seal Protection. or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

The vent system shall be designed to prevent a trap seal from being exposed to a pressure differential that exceeds one (1) inch of a water column (249 Pa) on the outlet side of the trap.


Slide49 l.jpg

908.2 Horizontal Wet Venting for Bathroom Groups. or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater.

908.2.1 Where Permitted. Water closets, bathtubs, showers and floor drains within one (1) or two (2) bathroom groups located on the same floor level and for private use shall be permitted to be vented by a wet vent. The wet vent shall be considered the vent for the fixtures and shall extend from the connection of the dry vent along the direction of the flow in the drain pipe to the most downstream fixture drain or trap arm connection to the horizontal branch drain. Each wet-vented fixture drain or trap arm shall connect independently to the wet- vented horizontal branch drain. Each individual fixture drain or trap arm shall connect horizontally to the wet-vented horizontal branch drain or shall be provided with a dry vent. The trap to vent distance shall be in accordance with Table 10-1. Only the fixtures within the bathroom groups shall connect to the wet-vented horizontal branch drain. The water closet fixture drain or trap arm connection to the wet vent shall be downstream of any fixture drain or trap arm connections. Any additional fixtures shall discharge downstream of the wet vent system and be conventionally vented.


Slide50 l.jpg

908.2.2 Vent Connection. The dry vent connection to the wet vent shall be an individual vent or common vent for the lavatory, urinal, bidet, shower, or bathtub. Only one (1) wet-vented fixture drain or trap arm shall discharge upstream of the dry-vented fixture drain connection.

908.2.3 Size. The wet vent shall be sized based on the fixture unit discharge into the wet vent. The wet vent shall be not less than two (2) inches (50 mm) in diameter for four (4) dfu or less, and not less than three (3) inches (80 mm) in diameter for five (5) dfu or more. The dry vent shall be sized in accordance with Tables 7-3 and 7-5 based on the total fixtures units discharging into the wet vent.


Chapter 10 traps and interceptors l.jpg
Chapter 10 vent shall be an individual vent or common vent for the lavatory, urinal, bidet, shower, or bathtub. Only one (1) wet-vented fixture drain or trap arm shall discharge upstream of the dry-vented fixture drain connection.Traps and Interceptors

  • Chapter 10 can be adopted as written.

  • Changes between the 2000 Maine State Internal Plumbing Code and the 2009 Uniform Plumbing Code include.

  • Table 10-1

  • 1004.1 Prohibited traps

  • 1014.0 through 1014.3.7 Grease Interceptors and Hydromechanical Grease Interceptors. Including tables

  • 10-2 & 10-3

  • 1015.0 FOG (Fats, Oils, and Greases) Disposal System.


Slide57 l.jpg

Traps vs. Interceptors vent shall be an individual vent or common vent for the lavatory, urinal, bidet, shower, or bathtub. Only one (1) wet-vented fixture drain or trap arm shall discharge upstream of the dry-vented fixture drain connection.

Nomenclature Clarification Recent changes in codes and standards to clarify mixed terms.

“Trap” has been eliminated in ASME Standards,

Uniform plumbing Code (UPC), and

Canadian Standards Association (CSA).

The International Plumbing Code (IPC)

“Interceptor” is deemed to be a more inclusive term

“Interceptor” allows for a more precise distinction between devices.

First official adoption was by IAPMO during its comprehensive rewrite of Chapter Ten (10) of the Uniform plumbing Code.


Slide58 l.jpg

The Hydromechanical Grease Interceptor vent shall be an individual vent or common vent for the lavatory, urinal, bidet, shower, or bathtub. Only one (1) wet-vented fixture drain or trap arm shall discharge upstream of the dry-vented fixture drain connection. design type incorporates air entrapment, the buoyancy of grease in water and hydro mechanical separation with interior baffling for grease, FOG (fats, oils and grease) separation . Hydromechanical Grease Interceptors continuously separate the FOG (fats, oils and grease) at the velocity it enters the interceptor.

The size of Hydromechanical Grease Interceptor is expressed in the gallons per minute flow (GPM) that the grease interceptor can accept and still remove 90 % plus, of the Fog (fats, Oils and grease) from the influent. The common sizes available today are 10, 15, 20, 25, 35, 50, 75, 100 GPM.


Slide61 l.jpg

SIZING OF HYDROMECHANICAL GREASE INTERCEPTORS: vent shall be an individual vent or common vent for the lavatory, urinal, bidet, shower, or bathtub. Only one (1) wet-vented fixture drain or trap arm shall discharge upstream of the dry-vented fixture drain connection.

The Uniform Plumbing Code (UPC) has two methods.

1. Using Gravity Flow Rates (Table 10-2

2. Using Fixture Capacity (Table 10-2)


Slide63 l.jpg

The Gravity Grease Interceptor vent shall be an individual vent or common vent for the lavatory, urinal, bidet, shower, or bathtub. Only one (1) wet-vented fixture drain or trap arm shall discharge upstream of the dry-vented fixture drain connection. design type

incorporates two or more compartments in series, a

minimum volume of 500 gallons and uses its larger

volume of water to slow theflow velocity down

allowing the time required for simple buoyancy of

grease, FOG (fats, oils and grease) in water to cause

separation. That is why the physical size of the

Gravity Grease Interceptor is so much greater than

the physical size of the Hydromechanical Grease

Interceptor.

With both design types the key to proper sizing

is understanding the “Size” nomenclature since it is

different for each type.

The size of a Gravity Grease Interceptor is based on the actual volume of water theinterceptor will hold expressed in gallons. Common Sizes available today are 500, 750, 1000, 1250, 1500, 2000, 3000 Gallons


Slide65 l.jpg

The discharge from food grinders (garbage disposals) is almost universally required to bypass the grease interceptor.

The food grinder (and the associated pre-rinse station at the dishwasher ) is one of the single greatest sources of FOG. Yet despite that fact, most codes forbid food grinders discharge from passing through a grease interceptor.

Technologically there is no reason for the waste stream to bypass the grease interceptor if the solids have been removed.


Chapter 11 storm drainage l.jpg
Chapter 11 almost universally required to bypass the grease interceptor.Storm Drainage

  • Chapter 11, Storm Drainage

  • a. The board does not adopt Chapter 1101.5, Subsoil Drains.

  • b. The board does not adopt Chapter 1101.6, Building Subdrains..

  • c. The board does not adopt Chapter 1101.7, Areaway Drains.

  • d. The board does not adopt Chapter 1101.8, Window Areaway Drains.

  • e. The board does not adopt Chapter 1101.9, Filling Stations and Motor Vehicle Washing Establishments.

  • f. The board does not adopt Chapter 1101.10, Paved Areas.

  • g. The board does not adopt Chapter 1102.5, Subsoil Drains.

  • h. The board does not adopt Chapter 1106.3, Size of Roof Gutters.

  • i. The board does not adopt Table 11-3, Size of Gutters.


Chapter 12 fuel piping l.jpg
Chapter 12 almost universally required to bypass the grease interceptor.Fuel Piping

Chapter 12, Fuel Piping. The board does not adopt Chapter 12, Fuel Piping.


Chapter 13 health care facilities and medical gas and vacuum systems l.jpg
Chapter 13 almost universally required to bypass the grease interceptor.Health Care facilities and Medical Gas and Vacuum Systems

Chapter 13, Health Care Facilities and Medical Gas and Vacuum Systems. The board does not adopt Chapter 13, Health Care Facilities and Medical Gas and Vacuum Systems.


Chapter 14 referenced standards table 14 1 l.jpg
Chapter 14 almost universally required to bypass the grease interceptor.Referenced Standards Table 14-1

  • Chapter 14 is adopted as written.

  • Changes between the 2000 Maine State Internal Plumbing Code and the 2009 Uniform Plumbing Code include.

  • Expanded listings and listing agency references.


Slide70 l.jpg

CHAPTER 14 almost universally required to bypass the grease interceptor.

MANDATORYREFERENCED STANDARDS

TABLE 14-1

The new Table 14-1 is substituted for the same in the 2009 UPC.

Cross references and updates have been added national standards are now clearly identified, and Editorial revisions have been made.


Chapter 15 firestop protection l.jpg
Chapter 15 almost universally required to bypass the grease interceptor.Firestop Protection

  • Chapter 15 is adopted in its’ entirety.


Chapter 16 nonpotable water reuse systems l.jpg
Chapter 16 almost universally required to bypass the grease interceptor.Nonpotable Water Reuse Systems

  • (9) Chapter 16, Nonpotable Water Reuse Systems.

  • a. The board does not adopt Part I, Gray Water Systems, in its entirety.


Chapter 16 nonpotable water reuse systems part ii reclaimed water systems l.jpg
Chapter 16 almost universally required to bypass the grease interceptor.Nonpotable Water Reuse SystemsPart IIReclaimed Water Systems

  • The board adopts reclaimed water system in its’ entirety.


Slide74 l.jpg

Part II almost universally required to bypass the grease interceptor.

1613.0 Reclaimed Water Systems – General.

(A) The provisions of Part II of this chapter shall apply to the installation, construction, alteration, and repair of reclaimed water systems intended to supply uses such as water closets, urinals, trap primers for floor drains, floor sinks, irrigation, industrial processes, water features and other uses approved by the Authority Having Jurisdiction. Potable water supplied as makeup water in these systems shall be protected against back-pressure and back-siphonage in accordance with Sections 602.0 and 603.0


Slide75 l.jpg

( almost universally required to bypass the grease interceptor.D) A reclaimed water system shall be designed by a person registered or licensed to perform plumbing design work.

1614.0 Definitions.

Reclaimed Water - Nonpotable water the meets or as a result of treatment, meets federal requirements for its intended uses. The level of treatment and quality of the reclaimed water shall be approved by the Authority Having Jurisdiction.


Slide76 l.jpg

1617.0 Pipe Material/Pipe Identification. almost universally required to bypass the grease interceptor.

Reclaimed water systems shall comply with Sections 1617.1 and 1617.2.

1617.1 Pipe Materials. Reclaimed water pipe, valves and fittings shall conform to the requirements of Sections 604.0, 605.0 and 606.0.


Slide77 l.jpg

1617.2 Color and Information. almost universally required to bypass the grease interceptor.Reclaimed water

systems shall have a purple background with black

uppercase lettering with the words “CAUTION:

RECLAIMEDWATER, DO NOT DRINK.”

1618.0 Installation

1619.0 Signs.

(A) Commercial, Industrial and Institutional Room Entrance Signs. All rooms in commercial, industrial, and institutional occupancies using reclaimed water for water closets and/or urinals shall be identified with signs.


Appendix a l l.jpg
Appendix A-L almost universally required to bypass the grease interceptor.

  • The provisions in the appendices shall not apply and shall be used only as a reference or guideline.