by Emergency Systems Service Company Distributor For: - PowerPoint PPT Presentation


by Emergency Systems Service Company Distributor For:. Generators – Automatic Transfer Switches- Accessories Technical Overview Presented by Emergency Systems Service Company.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha

Download Presentation

by Emergency Systems Service Company Distributor For:

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Slide1 l.jpg

by

Emergency Systems Service Company

Distributor For:

Your Partner for


Slide2 l.jpg

Generators – Automatic Transfer Switches- Accessories

Technical Overview

Presented by

Emergency Systems Service Company

Your Partner for


Slide3 l.jpg

Located in Quakertown, Pennsylvania, 40 miles Northwest of Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

Your Partner for


Slide4 l.jpg

Emergency Systems Service Company Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

Specializes in the Sales, Service, Rental, Planned Maintenance Contracts, Load Bank Testing, and Replacement Parts for Engine-Generator Sets and Automatic Transfer Switches

Company Personnel

Robert R. Hafich – President of Sales and Administration

Joseph M. Hafich – President of Service and Operations

Along with 38 other dedicated employees who make us one of the premier Katolight / MTU generator set distributors

Your Partner for


Emergency systems service compan y l.jpg
Emergency Systems Service Compan Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.y

  • Service

    - Employs 17 Service Technicians – Fully stocked Service Vans

    - Maintenance Service Contracts – Scheduled Repairs

    - 24/7 Emergency response Service

    - Over 800 Maintenance Contracts on over 1200 units

    - We service all Manufacturers such as Katolight/MTU, Kohler, Onan,

    Caterpillar, Cummins, Detroit Diesel, Asco, GE/Zenith,

    Cutler Hammer.

    - Resistive Load Bank Testing, up to 2000kw.

    - JCAHO and NFPA 110 Certification Testing

  • Parts

    -Extensive Parts Inventory for numerous Manufacturers.

    - Maintenance parts, Engine Parts, Control Parts, Accessories

Your Partner for


Rental generators l.jpg
Rental Generators Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Fleet of over 30 Mobile Generators for Rental Applications. Sizes from 22kw to 1000kw

  • 24/7 availability

  • Switchable Voltages

  • Diesel Engines with Base Mounted Fuel Tanks and Rupture Basin

  • Sound Attenuated Enclosures. Low DBA levels

  • Rental Cable available in multiple sizes and lengths

  • Rentals available for: Daily – Weekly – Monthly and long term

  • Available services include Transportation, Tie-ins.

Your Partner for


Rental automatic transfer switches l.jpg
Rental Automatic Transfer Switches Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • 200 Amp to 1600 Amp

  • Switchable Voltages

  • Nema 3R Enclosures

  • Equipped with time delays, Pilot lights and Exerciser

  • Tie in Cable available

  • Transportation and cable-in service

  • Weekly, Monthly or Long term rates available

Your Partner for


Mtu power generation l.jpg
MTU Power Generation Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Tognum acquired Katolight in April 2007

  • Katolight Established in 1952

    • Manufacturing, assembly, testing location for MTU Onsite Energy Power Generation. Located in Mankato, MN

Your Partner for


Generator product overview l.jpg
Generator Product Overview Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Diesel – 20 KW to 3250 KW (Latest EPA Tier Certified)

  • Natural Gas/LP – 25 KW to 130 KW (EPA Certified 1st qtr 2009)

    150 KW to 400 KW (EPA Certified 1st qtr 2010)

  • Available Voltages

    120/240 Single Phase

    120/240 Three Phase

    120/208 three Phase

    277/480 Three Phase

    Medium Voltage – 5 KV and 15 KV

  • Prime Movers

    Diesel - 20 KW to 275 KW – John Deere

    Diesel - 300 KW to 3250 KW – MTU (Detroit Diesel)

    Diesel - 550 KW & 600 KW Volvo

    Natural gas – 25 KW to 130 KW GM

    Natural Gas – 150 KW to 400 KW - Doosan

  • Generators:Marathon – Newage – Leroy Somer -

Your Partner for


Standard and optional accessories l.jpg
Standard and Optional Accessories Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Generators

    Temperature Rise – 150 degree C Standard (Optional 130, 105, 80)

    Oversized Generator Ends – Better performance for non-linear loads

    PMG (Permanent Magnet Generator) – Better performance for motor starting.

  • Cooling Systems

    Standard Unit Mounted Radiator with Duct Flange

    Optional Remote Radiator

    Optional Heat Exchanger

  • Governor

    Isochronous (+/- ¼% voltage and frequency regulation)

  • Control Panel

    Standard KDGC2020 Digital Control Panel.

    NFPA 110 Level 1 Compliant

    Monitors all Engine and Generator Parameters plus Safety Protection

    Generator Set can be Controlled and Monitored either Locally or Remotely

    Communications Capability – Open Protocol, RS232, RS485

    With Available Communication Options

    Modbus TCP/RTV

    Load Share Module for Internet Protocols

Your Partner for


Standard and optional accessories11 l.jpg
Standard and Optional Accessories Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Remote Annunciator Panel

    NFPA 110 Level 1 Compliant

    2 Wire Twisted Pair Communication Cable Belden Blue Hose Number 9463

    DC or AC Powered

  • Main Line Circuit Breakers

    Unit Mounted

    600V Rated

    80% Rated

    Thermal Magnetic Trip

  • Battery

    Sealed Lead Acid

    12 VDC or 24 VDC

    Polyethylene Battery Box

    Battery Cables

Available options include

100% Rated

Digital Electronic Trip

Ground Fault, Shunt Trip, Auxiliary Contacts

Battery Charger

Full Float Battery Charging

12 VDC or 24 VDC to match battery voltage

120 VAC Input (other voltages optional)

NFPA 110 Level 1 Compliant with monitoring and alarms

Loose or factory mounted and wired. (Open Power Units)

Factory mounted and wired (Enclosed Power Units)

Your Partner for


Standard and optional accessories12 l.jpg
Standard and Optional Accessories Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Silencers

    Critical and Hospital Grade

    Flexible Exhaust Connection

    Silencer and Flex provided loose for contractor installation ( Open Power Unit)

    Contractor provides and installs all extended piping, hangers, insulation, etc

    Silencer and Flex factory mounted.(Enclosed Power Units)

    Factory provides and installs all extended piping. (Enclosed Power Units)

    On Enclosed Power Units, silencer can be factory insulated and mounted inside the enclosure providing better

    aesthetics and sound attenuation

  • Block Heaters

    Output - 1000 watt to 12000 watt

    Input – 120 VAC Single Phase to 480 VAC Three Phase

    Factory Mounted on Open Power Units

    Factory Mounted and Wired on Enclosed Power Units

  • Enclosures (Enclosed Power Units)

    Weatherproof Skin Tight

    Weatherproof and Sound Attenuated Skin Tight

    Level 1 – Foam Insulation (Good)

    Level 2 – Foam Insulation with Intake and Exhaust Scoop (Better)

    Level 3 – Crystal Quiet Enclosure (Best)

    Weatherproof and Sound Attenuated Walk-In

    *Available Options on all enclosures include Aluminum Construction, Motorized Dampeners, Lighting Packages,

    Distribution Panels Panels, etc.

Your Partner for


Standard and optional accessories13 l.jpg
Standard and Optional Accessories Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Fuel Systems

    Diesel

    Double Wall Sub-Base Fuel Tank (24, 48, or 72 Hour Capacity)

    Optional Electrical Conduit Stub-Up Area Under MLCB

    Double Wall Sub-Base Fuel Day Tank (Remote Pumping Capability)

    Remote Day Tank (Remote Pumping Capability)

    UL142 and NFPA 30 Compliant

    Natural Gas, LP, LP Liquid Withdrawal

    Factory provides Fuel Flex, Fuel Solenoid, Y Strainer, and Flow Regulator Valve to operate on 4 oz. to 6 oz. (7-11 inches) of gas pressure.

  • Vibration Isolation

    Pad Style

    Spring Style

    Spring Seismic Style

  • Additional Accessories

    Trailer Mounted Units for Mobile Applications

    UL 2200

    Optional Colors (Gold, Tan, Gray Standard)

    Extended Warranties (2 year/3000 hour basic)

Your Partner for


Load banks l.jpg
Load Banks Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Load Banks are designed to provide electrical loads for testing Generator Sets and Uninterruptible Power Supplies (UPS). Load Banks are also used to reduce “Wet Stacking” problems in Diesel Engines on Backup Generator Sets.

  • Load Banks are available as:

    Permanent

    Portable

    Radiator Mounted

    Reactive

Your Partner for


Testing l.jpg
Testing Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Other Reasons to Test

    • JCAHO (Joint Commission on Accreditation of Healthcare Organizations)

    • Acceptance of NFPA-99-1999 section 3-4.4.1.1(b) calls for the EPS to be tested a minimum 12 times per year, at intervals no less than 20 days and no morethan 40 days.

Your Partner for


Emissions l.jpg
Emissions Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Emissions – 2011 and beyond

    • Standby rated generator sets – current configurations are anticipated to remain the same until approx 2011

      • EPA Tier 4 phase in period from approximately 2008-2015.

    • Most generator sets – will require after treatment to meet Tier 4 standards

    • 1/1/2009: spark ignited gensets will be required to be EPA certified

    • Economic Impact

      • Annual emission reductions are estimated at 738,000 tons of NOx, 129,000 tons of PM

      • By 2030 12,000 premature deaths would be prevented due to the implementation of these standards. (www.epa.gov)

Your Partner for


Automatic transfer switches l.jpg
Automatic Transfer Switches Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Manufacturers:

    Asco – GE/Zenith – Cutler Hammer - Russelectric

  • Styles:

    Contactor – Circuit Breaker

  • Types:

    Open Transition - Delayed Transition - Closed Transition

    Bypass Isolation

    Medium voltage

    Service Entrance Rated

    Paralleling Switchgear

    Static Switchgear

  • Sizes:

    30 to 4000 Amps - 120 to 4160 volts – 2,3, and 4 Pole

  • Enclosures:

    NEMA 1, 3R, 4, 4X, 12

  • Standard Features:

    Time Delays, In-Phase Monitors, Auxiliary Relays, Exerciser, Indicating Lights

  • Optional Features:

    Communications and Scada Systems, Peak Shave, Area Protection,

    Load Shed Controls

Your Partner for


Sales technical assistance l.jpg
Sales & Technical Assistance Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

  • Generator Sizing and Specification

  • Budgeting

  • Technical Installation Assistance

    - Recommended Options

    - Dimensions and Weight

    - Location

    - Fuel

    - Power requirements

    - Air Flow

    - Exhaust

  • Pre-Installation Assistance

  • Operating and Exercising Instruction

  • Proposal for Continued Planned Maintenance Contract

Thank you for your business and specifying our generator sets

Katolight by MTU Onsite Energy

Your Partner for


Slide19 l.jpg

Anywhere Reliable Power is Required Philadelphia. Established in 1974 by Joseph A. Hafich, we have been proudly serving the Delaware Valley and Lehigh Valley for over 30 years.

Rely On

“Emergency Power System Specialists”

www.emergencysystems-inc.com