BUILDING EXTERIOR
Download
1 / 22

INFO: This is an exterior entry door. The door cannot be locked. There are two deficiencies. - PowerPoint PPT Presentation

BUILDING EXTERIOR INFO: This is an exterior entry door. The door cannot be locked. There are two deficiencies. DEF: Damaged Hardware/Locks (Doors) - L3 Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3 BUILDING EXTERIOR

Related searches for INFO: This is an exterior entry door. The door cannot be locked. There are two deficiencies.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha

Download Presentation

INFO: This is an exterior entry door. The door cannot be locked. There are two deficiencies.

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


BUILDING EXTERIOR

INFO:This is an exterior entry door. The door cannot be locked. There are two deficiencies.

DEF:Damaged Hardware/Locks (Doors) - L3

Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3


BUILDING EXTERIOR

INFO:You see peeling and cracking on this exterior entry door.

DEF:Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3


BUILDING EXTERIOR

INFO:Exterior door.

DEF:Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3


BUILDING EXTERIOR

INFO:There are two deficiencies.

DEF:Damaged/Missing Screen/Storm/Security Door - L1

Damaged Surface (Holes/Paint/Rusting/Glass Doors) - L3


BUILDING EXTERIOR

INFO:The crack is > 3/8” width x 3/8” depth x 27” long.

DEF:Cracks/Gaps (Foundations) - L3


BUILDING EXTERIOR

INFO:There are two deficiencies. 15% of the wall is affected.

DEF:Spalling/Exposed Rebar (Foundations) - L2

Cracks/Gaps (Walls) – L2


BUILDING EXTERIOR

INFO:Exposed rebar.

DEF:Spalling/Exposed Rebar (Foundations) - L3


BUILDING EXTERIOR

INFO:There has been no rain for 3 days.

DEF:Damaged/Clogged Drains (Roofs) - L3


BUILDING EXTERIOR

INFO:None.

DEF:Damaged Soffits/Fascia (Roofs) - L3


BUILDING EXTERIOR

INFO:This is the only place on this painted building where you observe this condition.

DEF:Missing/Damaged Components from

Downspout/Gutter (Roofs) - L3


BUILDING EXTERIOR

INFO:None.

DEF:Missing/Damaged Components from

Downspout/Gutter (Roofs) – L2


BUILDING EXTERIOR

INFO:You observe this condition and it has not rained

for four days. Drain is functional.

DEF:Ponding (Roofs) - L3


BUILDING EXTERIOR

INFO:None.

DEF:Missing/Damaged Shingles (Roofs) – L1


BUILDING EXTERIOR

INFO:None.

DEF:Cracks/Gaps (Walls) – L3


BUILDING EXTERIOR

INFO:None.

DEF:Missing Pieces/Holes/Spalling(Walls) – L3


BUILDING EXTERIOR

INFO:None.

DEF:Missing Pieces/Holes/Spalling(Walls) – L3


BUILDING EXTERIOR

INFO:This is the only damage on this building wall.

DEF:Stained/Peeling/Needs Paint(Walls) – L1


BUILDING EXTERIOR

INFO:This is the only damage on this building wall.

DEF:Stained/Peeling/Needs Paint(Walls) – L1


CHANGE TO A DUPLEX PICTURE!

BUILDING EXTERIOR

INFO:This damage was observed on a sample building with no sample units.

DEF:Broken/Missing/Cracked Panes (Windows) - L3


BUILDING EXTERIOR

INFO:This damage was observed on a sample building with no sample units.

DEF:Broken/Missing/Cracked Panes (Windows) – L2


BUILDING EXTERIOR

INFO:This damage was observed on a sample building with no sample units.

DEF:Broken/Missing/Cracked Panes (Windows) - L3

Health & Safety - Other/Sharp Edges


BUILDING EXTERIOR

INFO: This ground floor bedroom window is one of the two means of egress from this room within a sample building with no sample units.

DEF: Security Bars Prevent Egress (Windows) - L3