Trace Cracking Problem

Trace Cracking Problem. Pitch Adapter (PA). 2-mil Kapton. ½ oz copper. Nominal 150 m -inch nickel, 10 m -inch gold. Printed Wiring Board (PWB). Nominal 1-mm radius. Cracked traces on PA after bonding. . History. Before fall 2004. ~25% rejection after bonding to PWB.

Antony
Download Presentation

Trace Cracking Problem

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Trace Cracking Problem • Pitch Adapter (PA). • 2-mil Kapton. • ½ oz copper. • Nominal 150 m-inch nickel, 10 m-inch gold. • Printed Wiring Board (PWB). • Nominal 1-mm radius. • Cracked traces on PA after bonding. Pitch Adapter Review 1/20/05

  2. History • Before fall 2004. • ~25% rejection after bonding to PWB. • Criterion: < 8 broken traces. • MCM production stopped for unrelated reasons. • Restart in 12/04. • 100% rejection after bonding. • (Almost) every trace is cracked, typically multiple cracks per trace. Pitch Adapter Review 1/20/05

  3. Two Groups of PWB • Nominal 1-mm radius. • “Un-deburred” PWB. • Measurement of profile. • Noticed some surface irregularity. • Gently abrade by hand. • “Deburred” PWB. Pitch Adapter Review 1/20/05

  4. Four Groups of Pitch Adapters Pitch Adapter Review 1/20/05

  5. Minimum Bend Radius Guideline • IPC-2223 guidelines. • 2-mil Kapton and ½ oz copper. • No nickel or gold! • “Flex to install” applicable here. • Also note ultimate elongation at break of 16%. Pitch Adapter Review 1/20/05

  6. Other Bend Radius Guidelines • Radius at least 10x thickness. • PA thickness = 68 mm. • Nominal radius = 1 mm, i.e. ~15x. • Rolled annealed copper grain parallel to direction of bend. • Perpendicular in case of Parlex PA. • Dyconex is electro deposited instead of RA. • Copper layer on neutral bend axis. • Not done here. • Is it possible? Pitch Adapter Review 1/20/05

  7. Intrinsic Bend Capability • Wrap PA around 1-mm aluminum form. • So far only PA Group C. • Add weight until problems show up. • Hairline cracks appeared at 5.5 lbs. • Visible cracks (conductive) appeared at 6.2 lbs. • Cracks became non-conductive at 9.0 lbs. • Conclude no intrinsic problems at 1-mm radius, but … More on this later Pitch Adapter Review 1/20/05

  8. 1-mm Radius Test Jig Pitch Adapter Review 1/20/05

  9. Bend Radius Observation at Teledyne • Use PWB in gluing fixture but no epoxy. • Clamp one side of PA (Group C). • Sweep PA over radius with “wiper blade”. • No additional tension. • Massive trace cracking. • Inconsistent with test jig results. • Trying to understand differences. Pitch Adapter Review 1/20/05

  10. Two Sets of Gluing Fixtures • Teledyne design. • Used in all production so far. • Four almost identical fixtures. • PA stretched during operation. • G&A design. • Used in a few tests. • One fixture. • PA sits in concave mold. • No pulling, hence no stretching. Pitch Adapter Review 1/20/05

  11. Teledyne Fixture Pitch Adapter Review 1/20/05

  12. Teledyne Fixture Design Flaw • Stretch PA ~1.5 mm. • Clear from design drawings. • Confirmed in test. • 1.5 mm / 16% = 1 cm. • PA full width ~6 cm. • Unrestrained part ~1 cm. • Certainly contributor to low yield. Pitch Adapter Review 1/20/05

  13. Recent Test Results Pitch Adapter Review 1/20/05

  14. Conclusion on PWB • Deburring or not is not the fundamental problem. • Similar problems using Group B PA. • Poor radius may be contributing factor. Pitch Adapter Review 1/20/05

  15. Conclusion on PA • Parlex Sep 04 and Nov 04 – no good. • Parlex Apr 04 – better. • Looking into what has changed. • Dyconex much better than bad Parlex PA. Pitch Adapter Review 1/20/05

  16. Conclusion on Fixture • Stretching is very bad. • 1.5 mm is near ultimate elongation. • Teledyne fixture only a contributing factor. • Earlier production yield ~75%. • Recent test with Apr 04 PA OK. • Problem common to all 4 fixtures. • G&A fixture OK with earlier PA, but similar problems with Nov 04 PA. Pitch Adapter Review 1/20/05

More Related